Page 34 • MN06150 ║ Issue/Rev. 0.7 (9/18)
Section IV – Diagrams
MNET Board
CN1
CN2
1 Tx-
2 Tx+
3 Rx+
4 Rx-
5
6
7
8
9
10
1
2
3
4
5
Promass
26
TX + / RX +
27
TX - / RX -
Figure 21. Promass Coriolis Meter Communications (RS485)
Programming
Parameter
microLoad
Promass
Baud Rate
38400
38400
Parity
8/No Parity/2 Stop bits
No Parity, 2 Stop bits
Modbus Endian
Big
Byte order 3-2-1-0
Sequence Number
1
Address 1
Mass Meter Type
E+H Promass
Timeout
0
Transmission Mode
RTU
Reply delay
10mS
Mode
Note:
Wiring example is shown on comm 2: comm 3 can be used as well.
Содержание Smith Meter microLoad.net
Страница 13: ...Issue Rev 0 7 9 18 MN06150 Page 13 Section IV Diagrams Figure 3 Opening microLoad net ...
Страница 16: ...Page 16 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Table 6 microLoad net I O Configuration Worksheet ...
Страница 29: ...Issue Rev 0 7 9 18 MN06150 Page 29 Section IV Diagrams Figure 16 RS 232 Shared Printing ...
Страница 30: ...Page 30 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Figure 17 RS 485 Shared Printing ...
Страница 37: ...Issue Rev 0 7 9 18 MN06150 Page 37 Section IV Diagrams Figure 24 AC Digital Outputs ...
Страница 40: ...Page 40 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Figure 26 Sample Application Worksheet ...
Страница 41: ...Issue Rev 0 7 9 18 MN06150 Page 41 Section IV Diagrams Figure 27 Sample Application AC Wiring ...
Страница 43: ...Issue Rev 0 7 9 18 MN06150 Page 43 Section IV Diagrams Figure 29 Sample Application Power Wiring ...