Page 22 • MN06150 ║ Issue/Rev. 0.7 (9/18)
Section IV – Diagrams
14
13
12
11
10
9
8
7
6
5 Shield
4
3
2 A-
1 A+
CN5
5
4 Gnd
3 +12Vdc
2
1
CN6
CN6
1
2
3 +12Vdc
4 Gnd
5
CN5
1 A+
2 A-
3
4
5 Shield
6 B+
7 B-
8
9
10
11
12
13
14
Promass
MNET Board
MNET Board
Promass, Single Pulse
Promass, Dual Pulse
22
25
24
23
23/25
22/24
Promass
Figure 9. Wiring Diagram, Promass
Promass Wire Codes
Terminal 22: +
Terminal 23: -
Terminal 24: +
Terminal 25: -
Note:
Pulse Inputs
• If EPLD (U24 chip) is Rev. 0, dual pulse will not function under 25 Hz. Only single pulse will count from 25 Hz
down to 3 Hz. Above 25 Hz, dual pulse will function as normal.
• If EPLD (U24 chip) is Rev. 1 or higher, dual pulse will function from 3 Hz and higher.
• Pulse doubling will not function for input pulses below 25 Hz.
• The pulse input circuitry has 1.6 k
Ω
of current limiting resistance “built-in” so that an external pull-up resistor is not
required when an open collector output device is connected as shown.
Содержание Smith Meter microLoad.net
Страница 13: ...Issue Rev 0 7 9 18 MN06150 Page 13 Section IV Diagrams Figure 3 Opening microLoad net ...
Страница 16: ...Page 16 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Table 6 microLoad net I O Configuration Worksheet ...
Страница 29: ...Issue Rev 0 7 9 18 MN06150 Page 29 Section IV Diagrams Figure 16 RS 232 Shared Printing ...
Страница 30: ...Page 30 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Figure 17 RS 485 Shared Printing ...
Страница 37: ...Issue Rev 0 7 9 18 MN06150 Page 37 Section IV Diagrams Figure 24 AC Digital Outputs ...
Страница 40: ...Page 40 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Figure 26 Sample Application Worksheet ...
Страница 41: ...Issue Rev 0 7 9 18 MN06150 Page 41 Section IV Diagrams Figure 27 Sample Application AC Wiring ...
Страница 43: ...Issue Rev 0 7 9 18 MN06150 Page 43 Section IV Diagrams Figure 29 Sample Application Power Wiring ...