Page 14 • MN06150 ║ Issue/Rev. 0.7 (9/18)
Section IV – Diagrams
Figure 4. MNET Board
Switch “S2” Functions
Switch 1: Reserved (must be OFF)
Switch 2: ON activates firmware upgrade on power up
Switch 3: See below
Switch 4: See below
Switch 5: ON resets security password on power up
Switch 6: Reserved (must be OFF)
Note:
Factory setting for all S2 switches is OFF
Switch 3
Switch 4
Function
OFF
OFF
No effect, program values used
ON
OFF
Forces IP address to 192.168.0.1
OFF
ON
Forces IP address to 10.0.0.1
ON
ON
Enables DCHP
Switch “S1” Functions (RS-485 termination)
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
COM1
COM1
COM2
COM2
COM3
COM3
Setting is OFF for RS-232 and ON for the last unit in the RS-485 communication line.
Note:
Factory settings for all positions of “S1” is OFF
Содержание Smith Meter microLoad.net
Страница 13: ...Issue Rev 0 7 9 18 MN06150 Page 13 Section IV Diagrams Figure 3 Opening microLoad net ...
Страница 16: ...Page 16 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Table 6 microLoad net I O Configuration Worksheet ...
Страница 29: ...Issue Rev 0 7 9 18 MN06150 Page 29 Section IV Diagrams Figure 16 RS 232 Shared Printing ...
Страница 30: ...Page 30 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Figure 17 RS 485 Shared Printing ...
Страница 37: ...Issue Rev 0 7 9 18 MN06150 Page 37 Section IV Diagrams Figure 24 AC Digital Outputs ...
Страница 40: ...Page 40 MN06150 Issue Rev 0 7 9 18 Section IV Diagrams Figure 26 Sample Application Worksheet ...
Страница 41: ...Issue Rev 0 7 9 18 MN06150 Page 41 Section IV Diagrams Figure 27 Sample Application AC Wiring ...
Страница 43: ...Issue Rev 0 7 9 18 MN06150 Page 43 Section IV Diagrams Figure 29 Sample Application Power Wiring ...