Electrical connection
When connecting the cable directly to the mains, connection to the electricity supply must
be made by an authorised person in accordance with the Wiring Rules AS/NZS3000. The
installation must include a suitable isolating switch with a minimum contact opening of 3mm
between the appliance and the mains. The isolating switch should be sized according to the
load on the data label and should comply with current regulations (the earth wire should not be
interrupted by the circuit breaker).
There must be a means for disconnection from the supply mains having a contact separation
in all poles that provide for full disconnection under overvoltage category III conditions
incorporated in the fixed wiring in accordance with the wiring rules.
The supply cable should be positioned so that it does not reach a temperature of more than
50°C along its entire length.
Before making the connection check that:
• The switch, wiring and electrical system can support the appliance load (see data plate);
• The power supply system has an efficient earthing connection which complies with the
provisions of current regulations;
• The power outlet or omnipoar circuit-breaker is easily accessible once the cooker has been
installed.
Replacing the power supply lead
If the supply cord or plug is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid hazard.
Warning:
All electrical connections must be made by a suitably qualified and licenced person in
accordance with local regulations.
Glen Dimplex will not be held responsible for damages caused to cabinetry due to incorrect
installation.