4. In next FLASH MEMORY UPDATE screen, confirm the procedure
and push [*UPDATE*] button again.
5. In next <PROGRAM VERSION INFO> screen, confirm the version
at “NOW(CURRENT) =“ column is “Ver F.F.”
If the version to update from disks is latest, proceed to update by [*
UPDATE*] button.
The program will be written into the FLASH ROM automatically.
Replace the floppy disk B (or No.2) when instructed.
6. When the operation is completed, “Completed!!” will be displayed
on the LCD.
7. Turn the power switch off and then back on again. Check the
instrument is functioning properly.
11. PRECAUTIONS BEFORE SERVICING
11.1. Precautions for measuring of the output waveforms
1. The waveform was measured with a “National Digital Storage
Oscilloscope VP-5730A”. Therefore the waveforms of musical tone
signals shown may differ somewhat due to the difference in the
timing of triggering.
2. Since the 1/10 test probe is used, the indicated voltage value on
the bottom part of each waveform illustration is 1/10 of the actual
value (e.g. 0.2 V/cm should be 2.0 V/cm).
3. To measure the waveforms, first set this unit to the service
diagnostic mode (refer to “Wave ROM test on
SERVICE
DIAGNOSTIC FUNCTION
”). The WAVE ROM output will then be
output as asine wave to facilitate the servicing check.
24
Содержание SX-PR1000
Страница 32: ...131 QMWG1047AA WHITE KEY G KEY 7 32 ...
Страница 50: ...Q105 2SD601AQ TRANSISTOR 1 2SD0601AQ MAIN 50 ...
Страница 53: ...R13 ERDS2FJ222 1 4W 2 2K 1 JACK2 53 ...
Страница 59: ...59 ...
Страница 62: ...62 ...
Страница 63: ...63 ...
Страница 64: ...64 ...
Страница 65: ...19 PACKAGING 65 ...
Страница 66: ... Printed in Japan S010800000 HM AM 66 ...