![Technics SX-PR1000 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/technics/sx-pr1000/sx-pr1000_service-manual_1068578019.webp)
LEDs light. If all switches are OK, “ALL SW OK” is shown on the
LCD. (If a switch is defective, nothing is shown.)
- To light all the LEDs, press and hold the DEMO button. If an LED
fails to light, the LED may be defective or there may be a break in
the surrounding circuit.
9.6. LCD module test (LCD adjustment and confirmation)
Figure-24
- Press the BW, CROSSTALK, SAMPLE or CONTRAST button to
begin the respective test.
BW:
All the dots light white and black. The display can be held by
pressing the DISPLAY HOLD button.
CROSSTALK:
An H pattern is shown. LCD crosstalk can be evaluated. To exit
this test, press the EXIT button.
SAMPLE:
Several display patterns shown during normal use are shown. The
display can be held by pressing the DISPLAY HOLD button.
CONTRAST:
The test pattern is shown. Adjust the contrast by the CONTRAST
control on the left of the LCD. To exit this test, press the EXIT
button.
- If the correct display is not shown during these tests, the LCD or
LCD drive circuit may be defective.
9.7. In & Out interface test
Figure-25