background image

 

 

 
 
 
 

WARNING! 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER ON THIS SPEAKER. THERE ARE NO 

USER-SERVICEABLE PARTS INSIDE. REFER ALL SERVICING TO A QUALIFIED TECHNICIAN 

The  lightning  flash  with  arrowhead  symbol  within  an  equilateral  triangle  is  intended to  alert  the  user  to  the  presence  of "dangerous"  voltage 
within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. Users should exhibit extra safety 
when this symbol appears in this instruction manual and follow all precautions as they are stated. 

The  exclamation  point  within  an  equilateral  triangle  is  intended  to  alert  the  user  to  the  presence  of  important  operating  and  maintenance 
(servicing) instructions in this manual. 
 

1- Read these instructions thoroughly before using this item. 
2- Keep these instructions for future reference. 
3- Heed all warnings. 
4- Follow all instructions. 
5- WARNING: To prevent fire or electric shock, do not expose this equipment to rain or moisture. Do not store or operate this product near any liquids. 
6- Clean only with a dry cloth. 
7- Do not store or operate this product near any heat sources such as radiators, heat registers, stoves, or other apparatuses (including amplifiers) that produce 
heat. 
8- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug 
has two blades and a round grounding prong. The wide blade or third prong is provided for your safety. If the provided plug does not fit your outlet, consult an 
electrician for the replacement of the obsolete outlet. 
9- Protect the all wires connected to this unit from being walked on or pinched, particularly plugs and the point where they exit from the unit. When removing 
the cord from the power outlet, remove it by holding the plug not by pulling the cord. 
10- Unplug the unit during lightning storms or when unused for long periods of time. 
11- When wiring this unit and all other equipment used in connection to this unit make sure that all of your equipment is turned OFF. 

12- This product is intended for indoor use only! To prevent risk of fire or shock, do not expose fixture to rain or moisture.   

13- Make sure the distance between the fixture and the lighted object is not less than 0.5 meters. Make sure there are no combustible or explosive objects 0.5 
meters around the fixture. Be sure that no ventilation slots are blocked. 

14- Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source.   
15- Secure fixture to fastening device using a safety chain.   
16- Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at temperatures higher than this.   
17- In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by 
unskilled people can lead to damage or malfunction. Please contact Technical Pro for the nearest authorized technical assistance center.   
18- Never connect the device to a dimmer pack.   
19- Make sure the power cord is never crimped or damaged.   
20- Never disconnect the power cord by pulling or tugging on the cord.   
21- Never carry the fixture directly from the cord. Always use the hanging/mounting bracket.   
22- Avoid direct eye exposure to the light source while it is on.   

23- Once installation and wiring is complete power on all your equipment with the volume and level controls turned DOWN. Once all the equipment is ON 
slowly raise the volume or level controls to their proper positions. 
24- When grounding this unit, be sure to do so correctly, so as not to defeat the built-in grounding in this unit. 
25- Before placing, installing, rigging, or suspending any product, inspect all hardware, suspension, cabinets, transducers, brackets and associated equipment 
for damage. Any missing, corroded, deformed, or non-load rated component could significantly reduce the strength of the installation, placement or array. Any 
such condition severely reduces the safety of the installation and should be immediately corrected. Use only hardware which is rated for the loading 
conditions of the installation and any possible short-term, unexpected overloading. Never exceed the rating of the hardware or equipment. 
26- Consult a licensed, Professional Engineer regarding physical equipment installation. Ensure that all local, state and national regulations regarding the 
safety and operation of equipment are understood and adhered to. 
27- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or 
plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate 
normally, or has been dropped. 

 

Introduction

   

Congratulations and thank you for your purchase of this Technical Pro LED stage effect light. To get the most from your unit 
it is recommended that you review all of the information provided in this instruction manual before operating this equipment. 

 

 

LGMEGAx 

Содержание LGMEGAx

Страница 1: ...User Manual for Professional DJ Multi Pattern Laser LED Stage Effect Light With DMX MODEL LGMEGAx...

Страница 2: ...isconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source 15 Secure fixture to fastening device using a safety chain 16 Maximum ambient temperature Ta...

Страница 3: ...rmally deformed As receiving a fixture carefully unpack the carton checking contents to ensure that all parts are in good condition Informing the shipper immediately and retaining packing material for...

Страница 4: ...imes prevents the unit from working at full performance or may even cause damages Don t install it on flammable object Don t use it when maximum ambient temperature is higher than 40 degree Unplug the...

Страница 5: ...at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated The device should be well fixed a free swinging mou...

Страница 6: ...unit is being operated in sound activated mode The fixture will illuminate changes according to the sound 10 Sensitivity Knob Use this knob to adjust the sensitivity of the lights when the fixture is...

Страница 7: ...ug so that it can fit in the outlet The only course of action you can take is to find another outlet which is properly equipped to handle a grounded plug or have an electrician upgrade your electrical...

Страница 8: ...female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S Maintaining the Fixture To maintain optimum performance and minimize wear fixtures should...

Страница 9: ...ress up or down to get Aut3 Press enter to get Sxxx xxx stand for 000 100 press up or down to increase or decrease the number to control the motor rotate speed re press the enter to confirm the curren...

Страница 10: ...utton until Soux x stand for0 1 6 press up or down to get Sou1 then press enter to confirm the current mode Sou4 RGBWA Mode Press the Func button until Soux x stand for0 1 6 press up or down to get So...

Страница 11: ...ay Effect Operation Instruction Auto Aut0 laser RGBWA 8 W 1 Press Func to get Autx 2 press Enter to get Sxxx 001 100 to adjust the speed 3 Press Enter to confirm the current mode Aut1 laser RGBWA Aut2...

Страница 12: ...Aut5 100 114 Aut6 115 129 Sou0 130 144 Sou1 145 159 Sou2 160 174 Sou3 175 189 Sou4 190 204 Sou5 205 219 Sou6 220 255 DMX mode work with CH2 3 4 5 6 7 8 CH2 All Auto modes 000 009 Blackout 010 014 Red...

Страница 13: ...000 004 No function 005 254 Strobe slow fast work with CH1 CH2 255 Sound activated strobe mode CH5 8pcs white LED control 000 009 blackout 010 019 Picture1 slow fast 020 029 Picture2 slow fast 030 039...

Страница 14: ...slave setup only ONE unit can act as the master ALL other fixtures must be set to d001 When using the master slave setup the fixtures can t be connected to a DMX controller as it would interfere with...

Отзывы: