CM Eth Combo
User Manual
50
5.3
Update via GB-A Port
1.
Power up the device.
2.
Apply “
0
” to “D” to
the rotary switch and adjust the batch-file for the update to the
current set IP-address of the device.
3.
Connect a Windows PC with a RJ45 cable directly to the GB-A-Port of the
CM_Eth_Combo
and make sure there is a link by checking the LEDs blinking. Do
not connect a switch in between.
4.
Start “
Flash ALL_10.104.3.XX.bat
” from the same folder as the firmware files are
stored.
Note
: If the update process is started with wrong IP-address, please interrupt by
closing the cmd-window. Then make a power reset and correct the IP-address in
the batch-file. The HOST-LED should blink fast. Restart update-process.
5.
Wait until “
Press any key
. . .“ appears in cmd
-window.
6.
Press any key
7.
Do a power reset
8.
Check the HOST-LED if blinking in normal mode.
9.
YES => check webserver by browser
NO => redo from point 4.
=> Finished
5.4
Update via 100BASE-T1 Port on the frontside (power
connector)
This option requires a
100BASE-T1 MediaConverter
or a
MediaGateway
to get access
to the device by the 100BASE-T1 Port. The illustration below shows the connection of
the devices in case of Media Gateway usage with our
MediaGateway
-Configuration-
File.
Figure 5-1: Schematic with MediaConverter