Keep Awake Reason Bus
:
This po
rt is supervised. If on this port is communication, CM_Eth_Combo can’t go
asleep.
This port is not supervised. The Capture Module can fall asleep even there is
communication on this port.
Section
: It is a
hexadecimal number. E.G “1A8”
It is a number assigned to any port separately. For further information see definition
of PLP-protocol. This value is used as VLAN-ID for the function
Use OuterVlan
s in
C
BusID
:
It is a hexadecimal number. E.G “B0”
It is a number assigned to this port and the paired port. (1A paired with 1B, 2A is paired
with 2B). For further information see definition of PLP-protocol.
Enable Injection for this port
:
If activate this function, you get access to a device directly connected on this
100BASE-T1 Port by a GB-Port. After activating please apply the IP-address of the
connected device
in the field “
IP for Injection
”
.
Note
:
Don’t forget to set “
IP for Injection
” on the specifi
c
GB
-Port.
Note
:
Don’t forget to configure the field “
Maximal delay (bytes) for Injection
”
No Injection possible on this port
IP for Injection
:
This field is available if the box “
Enable Injection for this port
” is
checked. Please fill in the IP-Address of the device directly connected on this port and
you want to get direct access by the GB-port.
Maximal delay (bytes) for Injection
:
This field is available if the box “
Enable Injection for this port
” is checked. Please fill in
a value many times higher than 512. The maximum is 1536 bytes. For higher
performance a small value is recommended.
This value is the maximum size of the possible inject frame, which is sent by the device
connected on the configured “
Output to
” GB
-port.
Time Stamp
: Timestamp in nano seconds [ns] resolution and accuracy of 40 nano
seconds [ns]
Messages Transmitted
: Counter for transmitted messages on this port from the
connected 100BASE-T1-device
Messages Received
: Counter for received messages on this port from the connected
100BASE-T1-device
Messages with Error
: Counter for received messages on this port from the connected
100BASE-T1-device containing an error. For example, CRC errors.