Technibel M2Z P Скачать руководство пользователя страница 5

GB

5

P

Q

Q

P

A BUS

BUS

BUS

Control box

With built-in ambient temperature sensor.
To be installed in zone 1.

Water

temperature,

zone 2

Heating

board

2-ZONE FLOOR MODULE

Water

temperature,

zone 1

Ambient

temperature,

zone 2

Ambient

temperature,

zone 1

Board, zone 2

A2

Board, zone 1

A1

Possible accessory

70250065

(If control box is installed

outside zone 1)

A BUS

- 2-conductor cable, min. size 1 mm

2

.

-

Total

length of the BUS connection: 40 meters (heating board / control box conn heating board / zone board if

any connection).

- To be connected on the terminal strip of the boards, zones 

A1

and 

A2

, located in the module.

A2

A1

Heating

board

Caution: 

Be sure to respect
the pola and -

P Zone ambient temperature sensor

- For zone 2, Floor: mandatory, supplied with the module.
- For zone 1, Floor: required only if the control unit is not placed in a

location that is representative of the temperature in zone 1.

Caution

In this case, the remote zone 1 sensor must be activated through
parameterisation on the control unit (refer to control’s technical manual).
This sensor is proposed as accessory 

70250065

.

- Wall mounting: the sensor is designed to be mounted in a "Mosaïc" type

(45 x 45), flush-mounted electrical box (not supplied).
It is to be installed in a location that is representative of the temperature
in the zone.

- The sensor must not be installed in corners, on shelves or behind

curtains, near sources or heat or directly exposed to sunlight.
The unit should be installed approximately 1.5 m above the floor.

- Use a 2-conductor cable for installation, minimum size: 0.5 mm

2

and max. length: 25 meters.

- To be connected directly on the corresponding zone board (terminals 

C

and 

S5

).

Q  Water temperature probe (Floor zone outgoing line)

- Indicated for informational purposes as it is already connected in the module.

1.50 m

20 cm min.

Ambient Sensor

HEATING MODULE

2-ZONE FLOOR MODULE

HEATING MODULE

Содержание M2Z P

Страница 1: ...ONAS SUELO HYDRAULIK MODUL F R 2 ZONEN FUSSBODEN HEIZUNG ODER K HLUNG M DULO 2 ZONAS SOALHO Mars 2009 10 11 465 F GB I E D P 02 Etiquette signal tique F GB I E D P NOTICE D INSTALLATION INSTALLATION I...

Страница 2: ...s of all current directives laws and regulations and according to recognized trade practices 1 3 VOLTAGE Before all operation check that the voltage indicated on the appliance rating plate corresponds...

Страница 3: ...ter sensor zone 2 16 Pressure taps for water output measurement zone 1 17 Pressure taps for water output measurement zone 2 2 PRESENTATION 2 1 DESCRIPTION 74 5 43 107 600 750 260 665 251 5 170 130 120...

Страница 4: ...Use the cable glands mounted on the unit see 4 2 4 Ensure that all installation grounds are interconnected Cables are not supplied Consult the module electrical diagram Also consult the installation...

Страница 5: ...ocation that is representative of the temperature in zone 1 Caution In this case the remote zone 1 sensor must be activated through parameterisation on the control unit refer to control s technical ma...

Страница 6: ...GURATION SETTING Set the button on the installation s control box to OFF Turn installation and module power on On the control unit configure the system for the 2 Floor Zones application parameter 70 2...

Страница 7: ...leeders located in the 2 zone module and heating module CAUTION An incorrect purge could result in malfunctions and damage to the heater of the heating module 0 10 20 30 40 50 60 70 80 90 0 0 5 1 1 5...

Страница 8: ...RAL MAINTENANCE All equipment must be properly maintained in order to provide optimum performance over time Faulty maintenance can result in the cancellation of the product guaranty Depending on the p...

Страница 9: ...GB 9...

Страница 10: ...F GB D P I E...

Страница 11: ...F GB D P I E...

Страница 12: ...dificarli senza preaviso En el inter s de mejoras constantes nuestros productos pueden modificarse sin aviso pr vio Unsere Produkte werden laufend verbessert und k nnen ohne Vorank ndigung abge ndert...

Отзывы: