Free Match D.C.inverter Muti-variable Air Conditioner Outdoor Unit
5
The following rules should be followed when the installation location is being considered so as
to let the unit run well enough.
1) The discharged air from the outdoor unit won’t return back and enough space should be left
for maintenance around the unit.
2) The installation location should be in good condition so that the unit is able to take in and
discharge enough air. Besides, make sure there is no obstacle at the air inlet/outlet of the
unit. If there is, remove it.
3) The unit must be installed where it is secure enough to support the weight of the unit and
capable of reducing to some extent noise and vibration to make sure they do not bother
your neighbors.
4) The designated lifting hole must be used for lifting the unit and protect the unit carefully
during lifting to prevent damaging the mental sheet which would result in rusting in future.
5) The unit should be installed where there is as little as direct sunlight.
6) The unit must be installed where the rain water and defrosting water can be drained.
7) The unit must be installed where the unit won’t be covered by the snow and won’t be
affected by rubbish and oil fog.
8) Rubber or spring shock absorbers should be used during the installation of the outdoor unit
to meet the noise and vibration requirements.
9) The installation dimensions should meet the requirement covered in this manual and the
outdoor unit must be fixed securely.
10) The installation should be carried out by the professionally skilled personnel.
(2) Installation of the Outdoor Unit
1) Outline dimension of the outdoor unit.
GWHD(36)NK3AO GWHD(36)NK3BO
572
378
1022
950
840
96
350
76
110
412
340
192
76
45
0
99
1015
1103
1087
191
631
44
0
40
1
36
2
12
1
Fig.3 Fig. 4