3
2-2. Major Component Specifications
2-2-1. Outdoor Unit
Outdoor Unit
GRF314MR5IAA
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Control PCB / HIC PCB / Filter PCB
POW-CM5A1-C-T / CR-HIC50A2-C-T / POW-CM5B1-C-T
Compressor
Type
DC Twin Rotary (Hermetic)
Compressor model
C-9RVN273H0W 80867080
Compressor oil … Amount
cc
FVC68S … 1900
Coil resistance (Ambient temp. 25°C)
Ω
R – S: 0.169
S – T: 0.169
T – R: 0.169
Safety devices
CT (Peak current cut-off control)
YES
Compressor discharge temp. control
YES
Operation cut-off control in abnormal ambient temp.
—
Run capacitor
µF
—
VAC
—
Crankcase heater
25W 240V
Fan & Fan Motor
Type
Propeller
Q’ty … Dia.
mm
1 … ø460
Fan motor model … Q’ty
KFC6S-61C3PA-C … 1
No. of poles … rpm (220V, High)
6 … 712
Nominal output
W
60
Coil resistance (Ambient temp. 20°C)
Ω
BRN – WHT: 66.53
WHT – YEL: 33.95
YEL – PNK: 12.50
Safety devices
Type
Thermal protector
Operating temp.
Open
°C
130 ± 8
Close
°C
79 ± 15
Run capacitor
µF
5
VAC
440
Heat Exchanger Coil
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.4
Face area
m
2
0.630
External Finish
Acrylic baked-on enamel finish