– 8 –
1. SPECIFICATIONS
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. SPA250R5TAA
Source 220 - 230 - 240 V / 1 phase / 50Hz
Remote Controller (option) Wired : K70D026ZAA / Wireless : K70D027ZAA
Controller P.C.B. Ass’y CR-X253GH (Microprocessor)
Fan (Number…diameter) mm Centrifugal (4...ø130)
Fan Motor
Model…Nominal output W KFG4Q–41A5P...40 W
Source 220 - 230 - 240 V / 1 phase / 50Hz
No. of pole…r.p.m. (230 V, High) rpm. 4...1,198
Coil resistance
Ω
BRN – WHT :
175.1 , ORG – YEL : 70.9
(Ambient temperature 20
°
C) WHT – VLT : 43.6 , WHT – PNK : 15.6
VLT – ORG : 27.0
Safety device
Operating temperature Open
°
C 130
±
5
°
C
Close
°
C Differential 15 deg. (min.)
Run capacitor VAC,
µ
F 440 V, 2.5
µ
F
Electronic refrigerant control valve
Solenoid control model DKV-MOZS550E0
Coil resistance (at 20
°
C)
Ω
ORG – GRY :
46 , YEL – GRY :
46
RED – GRY :
46 , BLK – GRY :
46
Solenoid control valve model IKV-24D12
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows…fin pitch mm 3…1.7
Face area m
2
0.170
Auto louver motor MC8 D
Auto louver motor...Rated V, Hz, W, rpm. 220 - 240 VAC, 50 Hz, 3 W, 3.3 rpm. 8P
Coil resistance (at 25 ˚C)
Ω
14,900
Ω
±
8 %
Dew proof heater V, W 240 V, 15 W