In case air ducting, the speed fan
m
ust be changed (see § «Change of
fan speed»
Outdoor air
Heated or
unheated room
0,5 m mini
2 m mini
2.3 - Installation with air duct
2.4 - Air duct sizing
The connection of
':+3
must be done using insulated air ducts of a nominal diameter of 160mm. The piping
can be connected either on the intake side, the blowing side or both.
Maxi
m
u
m
length
of ducts + elbow (1
m
) =
Flexible duct : 10
m
Rigid duct : 20
m
Example :
(1) : Elbow 70°C – ø160 (Réf. 710133)
(2) : Insulated flexible hose
ø160 1g 10m
(Réf. 710137)
Silent flexible hose
with ø160 sleeve Ø160
(Réf.
710136)
(1)
(2)
2.5 - Plumbing connections
• It is mandatory to install a
QHZ
pressure-relief valve (not included) set to 7 bars on the domestic cold water
supply of the device. Membrane type valve are recommended.
This pressure-relief valve must conform to the domestic standard.
• The pressure-relief valve must be installed as close as possible to the cold water inlet of the device and
WKH
SDVVDJHRIZDWHUPXVWQHYHUEHKLQGHUHG
by any accessory (valve, pressure controller, etc...)
• The drain outlet of the pressure-relief valve must be sized following the requirements of construction
standard and must never be blocked. It must be connected by use of a funnel, allowing a minimum
20mm open space, to a vertical draining pipe of a diameter equal to the piping connection of the device.
• The drain outlet of the pressure-relief valve must be installed in a frost-free place and pointing downward.
• If the pressure of the domestic cold water supply is higher than 5 bars, install a pressure reducer above the
pressure-relief valve at the beginning of the installation (a pressure of 4 to 5 bars is recommended).
• It is advised to install a shut-off valve above the pressure-relief valve.
• In cases of installations equipped with
- piping of a small diameter
- ceramic plate valves
it is necessary to install, as close as possible to the shut-off valves, a domestic expansion vessel adapted to
the installation.
• For the do
m
estic hot water circuit, use the following
m
aterials:
-
copper
- galvanised steel
-
brass
Depending on
m
aterials used in the hot water circuit, inco
m
patibilities could result in da
m
age due
to corrosion.
¢
£
¤
¥
¦
§
¨
¨
§
¦
©
ª
¤
«
§
¤
¬
§
¨
®
«
¯
°
±
£
²
³
®
±
´
µ
±
¯
¶
³
¯
µ
±
·
¸
«
·
¢
Содержание D.W.H.P
Страница 4: ... F G H I J K L L K J M N H O K H P K L Q R O S T U G V W R U X Y U S Z W S Y U O F ...
Страница 6: ... t u v w x y z z y x v y v y z u t ...
Страница 22: ...4 7 Parts list ä å æ ç è é ê ê é è ë ì æ í é æ î é ê ï ð í ñ ò ó å ô õ ð ó ö ó ñ ø õ ñ ó ù ú í ù ä ...
Страница 28: ...6 3 Cabling schematic 28 INSTALLATION MANUAL DOMESTIC HOT WATER HEAT PUMP ...