background image

CAF 187 R5IAA

Controller PCB

Part No.
Controls
Control circuit fuse

Remote Control Unit

Fan & Fan Motor

Type
Q'ty ……. Dia. and lenght

mm

Fan motor model…Q'ty
No. of poles…rpm (230 V, High / 2nd / 3rd / Low)
Running Amps

A

Power input

W

Coil resistance (Ambient temp. 20 °C )

Safety devices

Type
Operating temp. Open

°C

Close

Run capacitor

µF

VAC

Flap Motor

Type
Model
Rating
Coil resistance (Ambient temp. 25 °C )

Heat Exch. Coil

Coil
Rows
Fin pitch

mm

face area

m2

DATA SUBJECT TO CHANGE WITHOUT NOTICE

61

BLU-BRN: 33,9÷39,1

CB-XRV184EH
Microprocessor

250 V - 3,15 A

RCS-4MHVPNW4EX

Centrifugal fan

1…. Ø 280 / L 166

K35407 M01972 …1

4… 950 / 790 / 700 / 300

0,27

BLU-BLK: 325÷374

Internal thermal protector

150 ± 10 

Automatic

BLK-GRY: 78,7÷90,5

GRY-RED: 49,7÷57,2

RED-WHT/YEL: 155÷178

2

400

Stepping motor

MP24GA2

400±7%

DC 12 V

Aluminium plate fin  / Copper tube

1

1,3

0,258

7

Содержание 38.7106.005

Страница 1: ...5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA 0 8180 533 1 06 2008 SPLIT SYSTEM AIR CONDITIONER Model No Product Code No CAF97R5IAA CAF127R5IAA 38 7106 005 38 7106 006 38 7106 016 38 7106 007...

Страница 2: ...w wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line...

Страница 3: ...rain Pump and Float Switch 15 5 TEST RUN 16 5 1 How to Test Run the Air Conditioner 16 6 TROUBLESHOOTING 17 6 1 Precaution before Performing Inspection or Repair 17 6 2 Method of Self Diagnostics 18 6...

Страница 4: ...filter Dimensions Weight Dimensions Unit Height mm Width mm Depth mm Ceiling panel Height mm Width mm Depth mm Package dimensions Unit Height mm Width mm Depth mm Volume m3 Ceiling panel Height mm Wid...

Страница 5: ...ons Unit Height mm Width mm Depth mm Ceiling panel Height mm Width mm Depth mm Package dimensions Unit Height mm Width mm Depth mm Volume m3 Ceiling panel Height mm Width mm Depth mm Volume m3 Weight...

Страница 6: ...g temp Open C Close Run capacitor F VAC Flap Motor Type Model Rating Coil resistance Ambient temp 25 C Heat Exch Coil Coil Rows Fin pitch mm face area m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE K35407 M...

Страница 7: ...tor F VAC Flap Motor Type Model Rating Coil resistance Ambient temp 25 C Heat Exch Coil Coil Rows Fin pitch mm face area m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE 61 BLU BRN 33 9 39 1 CB XRV184EH Micro...

Страница 8: ...g 0 4 l min BI 1300 2725 230 V AC DC 0 5 A PC 309564003 220 240 V 50 Hz 14 W Primary WHT WHT 307 10 Secondary BRN BRN 1 8 10 ATR I55 AC 230 V 50 60 Hz 13 7 V 0 4 A 5 48 VA C7 M3 SY 25 C 60 RH 5 RH 31...

Страница 9: ...2 DIMENSIONAL DATA Unit mm REFRIGERANT TUBING JOINT WIDE TUBE CAF97 127R5I CAF98 128MR5I o d 9 52 3 8 CAF187R5I o d 12 7 1 2 9...

Страница 10: ...3 ELECTRICAL DATA 3 1 Electric Wiring Diagrams CAF 97 127 R5IAA CAF 187 R5IAA CAF 98 128 MR5IAA 10...

Страница 11: ...4 FUNCTIONS 4 1 Operation Functions 11...

Страница 12: ...12...

Страница 13: ...4 2 Protective Functions 13...

Страница 14: ...14...

Страница 15: ...4 3 Drain Pump and Float Switch 15...

Страница 16: ...5 TEST RUN 5 1 How to Test Run the Air Conditioner display area HIGH POWER button 1HR TIMER button ON OFF operation button 16...

Страница 17: ...6 TROUBLESHOOTING 6 1 Precaution before Performing Inspection or Repair 6 2 Method of Self Diagnostics ON OFF button 1HR TIMER button ACL reset button 17...

Страница 18: ...ics lamps Since the indications cover various units the corresponding parts listed below may not be present in some models 2 If the self diagnostics function fails to operate OPERATION lamp TIMER lamp...

Страница 19: ...6 3 Checking the Indoor and Outdoor Units 19...

Страница 20: ...6 4 Noise Malfunction and Electromagnetic Interference 20...

Страница 21: ...7 CHECKING ELECTRICAL COMPONENTS 7 1 Measurement of insulation Resistance 21...

Страница 22: ...7 2 Checking Continuity of fuse on PCB Assy 7 3 Checking Motor Capacitor 22...

Страница 23: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...

Отзывы: