background image

 

14

Troubleshooting 

Symptom 

Possible Cause / Solution 

Check for power on mains 

No Power 

Check main fuse and fuse holder 

Check data cables: connection and proper wiring 

Check Display settings 

Erratic / No response to DMX 

Check Start Address 

Check Start Address 

Check for overlapping addresses 

Check Menu settings 

Incorrectly responds to DMX 
(Diagnostic technique for DMX issues: Set 
suspect fixture’s Start Address the same as a 
correctly functioning fixture. If both units then 
function correctly, issue is programming) 

Check Data cables (faults and proper wiring) 

 
 

DMX-512 Background 

DMX-512 is a digital data transmission standard developed by the United States Institute for Theater Technology 
(USITT).  It is designed to enable control of lighting equipment.  DMX deals solely with the formatting of data for 
transmission and does not dictate how the data is created or used. 
 
Under DMX, signals are transmitted in much the same way a computer modem transmits data.  The Data, divided 
into channels, is "Framed" using a start bit, high (1), eight data bits and finally, two stop bits, both high (1). DMX 
uses no parity to check the integrity of the signal.  Instead, DMX relies on the ultra low probability of an error 
occurring in the same place when the data is resent.  The rate at which data is sent is fixed at 250k bps, almost four 
and a half times faster that a 56k modem.   This speed allows all data on a DMX chain to be updated more than 44 
times every second. 
 
The transmitted data follows a specific format. DMX allows for 512 channels each with eight data bits, giving each 
channel the possibility of 256 values.  When a data "Packet" is sent, all channels are transmitted one after another.  
Even if the data on a specific channel has not been changed, it must be sent.  In a packet, a "start code" of all zeros 
is sent before the data to identify the signal as a Standard DMX transmission.  This start code is transparent to the 
user and is handled by the controller. 
 
The physical signals are transmitted using a twisted pair of wires and a common shield, a configuration called 
Balanced.  The controller and all receiving equipment are connected using a “Daisy Chain" connection.  The signal 
is jumped from the controller to a piece of DMX equipment.  From there, the signal is jumped to the next piece of 
equipment and so on until the last piece of equipment is connected.  No branches are allowed and the signal does 
not come back to the controller.  The final piece of equipment will have only one cable connection.  As a result, all 
equipment connected to the chain will see exactly the same signal whether it is first or last.  When connecting 
equipment, no particular attention needs to be paid to the order in which the equipment is connected.  Depending on 
the conditions and equipment, a line terminator may be required.  If there is any question, in most circumstances the 
addition of a terminator will not degrade the signal.  To make a terminator, attach a 120-ohm resistor between the 
Signal Data Negative and Signal Data Positive pins of a connector in the last piece of equipment in the chain. 
 
The DMX Standard uses 5 pin XLR connectors.  However, it is common to see 
fixtures with 3 pin XLR connectors as these types of balanced or “Lo-Z” cables 
are common in the audio industry.  In either case, pin numbers are the same and 
carry the same signals.  
 

 
10900 Palmbay Drive • Orlando, FL 32824 U.S.A. 
www.techni-lux.com 

Pin 

Connection 

Common (Shield) 

Data Negative (S- or Cold) 

Data Positive (S+ or Hot) 

n/c (not used) 

n/c (not used) 

Содержание UltraLED Series

Страница 1: ...Information specifically for DL LEDBANK4 3TC v1 0 This manual contains important information Please read before operating fixture ...

Страница 2: ... to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied ...

Страница 3: ... Built in Program Chase Operation P01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 10 DMX Channel Assignments 11 6 Channel Mode 12 9 Channel Mode 12 12 Channel Mode 12 15 Channel Mode 12 Maintenance 13 Accessory Items sold separately 13 Troubleshooting 14 DMX ...

Страница 4: ... 7 26 lbs 3 3kgs Housing Material Aluminum Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Automatically adjusting from 100 to 240vAC 50 60Hz Rated Power 100W Fuses 2 amp mini size 5x20mm Control Digital Protocol USITT DMX512 1990 Channels 6 9 12 or 15 maximum Data I O 3 Pin ...

Страница 5: ...ith a Return Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to shipping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility C...

Страница 6: ...positioning when mounted Several clamp mounting holes in diameter are provided Knobs on both sides of the bracket provide locking tension preventing movement when tightened down Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixture will be exposed to water or rain high humidity extreme temperature changes or restricted ventilati...

Страница 7: ...rent program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode Select the desired chase from P01 to P14 using the UP DOWN buttons Press the ENTER button to select speed and flash settings respectively You can select the desired values via the UP DOWN buttons Speed is from slowest 00 to fastest at 99 Set strobe flashing...

Страница 8: ...up automatically in a continuous loop Press the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN buttons Please press the ENTER button to confirm and to exit the AUTO Mode Slave Operation The master slave operation enables several LED Banks to be synchroni...

Страница 9: ...stem s DMX controller to select a desirable addressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 6 channels of DMX if set to a Start Address of 7 it would use data from channels 7 and 8 9 10 11 12 Choose a Start Address so the channels us...

Страница 10: ...ddress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wish the fixture to use first Your choices are 6 9 12 or 15 channel modes This will determine the spacing of channels you will need to avoid overlapping of channels when selecting your start addresses E...

Страница 11: ...modes DMX Channel Mode Descriptions In the 6 9 and 15 channel modes the first 3 channels 1 2 3 function the same as described in the 6 channel mode table 6 channels Bank completely operates as 1 complete section only 9 channels Bank is divided into 2 sections of 2 groups of trileds 12 channels Bank is divided into 4 sections of 1 group of trileds without any macro master dimmer or strobe function ...

Страница 12: ... 143 153 Flow 1 Speed 0 255 Strobe 0 255 154 164 Flow 2 Speed 0 255 Strobe 0 255 165 175 Flow 3 Speed 0 255 Strobe 0 255 176 186 Flow 4 Speed 0 255 Strobe 0 255 187 197 Flow 5 Speed 0 255 Strobe 0 255 198 208 Flow 6 Speed 0 255 Strobe 0 255 209 219 Flow 7 Speed 0 255 Strobe 0 255 220 230 Flow 8 Speed 0 255 Strobe 0 255 Color select 231 241 Flow 9 Speed 0 255 Strobe 0 255 Color select 242 255 Sound...

Страница 13: ...compressor use low pressures and extreme care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black...

Страница 14: ...smitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration cal...

Отзывы: