background image

 

13

Maintenance 

Make sure fixture is cool and disconnected from power mains before any service. 

 

 

Weekly operating hours and environmental conditions will establish how often the fixtures need 
cleaning.  Fixtures should be cleaned and inspected at least once a month to maintain optimum 
performance.  Accumulation of dust and fog residue increases heat build up, can lead to 
malfunctions, overheating and reduction in maximum light output, reduced fixture life and over 
all performance.  Before conducting any maintenance, disconnect fixture from power mains.   
  
1) Disconnect fixture from power mains. 
2) Use a vacuum with a soft brush to remove dust collected on external vents and internal 
components.  If using an air compressor, use low pressures and extreme care to prevent 
damaging any internal parts or effects. 
4) Clean all optical elements when the fixture is cold.  Use a soft lint free cotton cloth or tissue 
and cleaner safe for plastics.  
5) Inspect clamps and safety cables to ensure fixture is secure and safe. 
 
 

Accessory Items 

(sold separately)

 

 

Order Code 

Description 

CLAMP-MEGA/B 

Mega Heavy Duty Aluminum Clamp – Black 

CLAMP-CBHALF 

Half Cheeseborough Coupler 300kg Max Load  

 

 

SAFETYCABLE30B 

Safety Cable Black 30” 

SAFETYCABLE30S 

Safety Cable Silver 30” 

 

 

CA-XLR3/10 

Pre-made 10’ 3-pin XLR Cable 

CA-XLR3/25 

Pre-made 25’ 3-pin XLR Cable 

CA-XLR3/50 

Pre-made 50’ 3-pin XLR Cable 

CA-XLR3/100 

Pre-made 100’ 3-pin XLR Cable 

 

 

CO-XLR3M   

XLR Connector 3-pin Male 

CO-XLR3F 

XLR Connector 3-pin Female 

 

 

CO-XLRTERM3 

XLR 3 Pin Data Terminator 

 

 

CO-XLR3MTO5F 

XLR 3 Pin Male to 5 Pin Female Adapter 

CO-XLR5MTO3F 

XLR 5 Pin Male to 3 Pin Female Adapter 

 

 

 

 

 

 

Содержание UltraLED Series

Страница 1: ...Information specifically for DL LEDBANK4 3TC v1 0 This manual contains important information Please read before operating fixture ...

Страница 2: ... to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanied ...

Страница 3: ... Built in Program Chase Operation P01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 10 DMX Channel Assignments 11 6 Channel Mode 12 9 Channel Mode 12 12 Channel Mode 12 15 Channel Mode 12 Maintenance 13 Accessory Items sold separately 13 Troubleshooting 14 DMX ...

Страница 4: ... 7 26 lbs 3 3kgs Housing Material Aluminum Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Automatically adjusting from 100 to 240vAC 50 60Hz Rated Power 100W Fuses 2 amp mini size 5x20mm Control Digital Protocol USITT DMX512 1990 Channels 6 9 12 or 15 maximum Data I O 3 Pin ...

Страница 5: ...ith a Return Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to shipping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility C...

Страница 6: ...positioning when mounted Several clamp mounting holes in diameter are provided Knobs on both sides of the bracket provide locking tension preventing movement when tightened down Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixture will be exposed to water or rain high humidity extreme temperature changes or restricted ventilati...

Страница 7: ...rent program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode Select the desired chase from P01 to P14 using the UP DOWN buttons Press the ENTER button to select speed and flash settings respectively You can select the desired values via the UP DOWN buttons Speed is from slowest 00 to fastest at 99 Set strobe flashing...

Страница 8: ...up automatically in a continuous loop Press the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN buttons Please press the ENTER button to confirm and to exit the AUTO Mode Slave Operation The master slave operation enables several LED Banks to be synchroni...

Страница 9: ...stem s DMX controller to select a desirable addressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 6 channels of DMX if set to a Start Address of 7 it would use data from channels 7 and 8 9 10 11 12 Choose a Start Address so the channels us...

Страница 10: ...ddress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wish the fixture to use first Your choices are 6 9 12 or 15 channel modes This will determine the spacing of channels you will need to avoid overlapping of channels when selecting your start addresses E...

Страница 11: ...modes DMX Channel Mode Descriptions In the 6 9 and 15 channel modes the first 3 channels 1 2 3 function the same as described in the 6 channel mode table 6 channels Bank completely operates as 1 complete section only 9 channels Bank is divided into 2 sections of 2 groups of trileds 12 channels Bank is divided into 4 sections of 1 group of trileds without any macro master dimmer or strobe function ...

Страница 12: ... 143 153 Flow 1 Speed 0 255 Strobe 0 255 154 164 Flow 2 Speed 0 255 Strobe 0 255 165 175 Flow 3 Speed 0 255 Strobe 0 255 176 186 Flow 4 Speed 0 255 Strobe 0 255 187 197 Flow 5 Speed 0 255 Strobe 0 255 198 208 Flow 6 Speed 0 255 Strobe 0 255 209 219 Flow 7 Speed 0 255 Strobe 0 255 220 230 Flow 8 Speed 0 255 Strobe 0 255 Color select 231 241 Flow 9 Speed 0 255 Strobe 0 255 Color select 242 255 Sound...

Страница 13: ...compressor use low pressures and extreme care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black...

Страница 14: ...smitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration cal...

Отзывы: