background image

 

IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited  Warranty:  This  warranty  covers  defects  or  malfunctions  in  this equipment.  This warranty lasts 
for  a  period of  two years 

from date of purchase.  It is the owner’s responsibility to provide invoices for 

proof  of  purchase,  purchase  date  and  dealer  or  distributor.    If  purchase  date  can  not  be  provided, 
warranty period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace 
parts or equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, 
belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items 
or  any  problem  resulting  from  the  following:  improper  wiring,  incorrect  voltage  (including  low  or  over 
voltage  conditions  and  lightning),  abuse,  misuse,  improper  maintenance  or  an  act  of  God  or  damage 
resulting  from  shipping.    Warranty  will  be  null  and  void  if  the  product  is  altered,  modified,  misused, 
damaged, or subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.  Any liability for consequential and incidental damages is expressly disclaimed.  No other warranty, 
expressed  or  implied  is  made.    Techni-Lux  liability  in  all  events  is  limited  to,  and  shall  not  exceed,  the 
purchase price paid. 
 
Returning  equipment  and  Repairs:    All  returns  must  be  accompanied  by  a  Return  Merchandise 
Authorization (RMA) number  and sent pre-paid.   Contact the dealer or Techni-Lux directly to obtain an 
RMA.    The  RMA  number  must  be  clearly  listed  on  the  shipping  label.    Due  care  must  be  exercised  in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed  problem  or  error  encountered.    Techni-Lux  is  solely  responsible  for  determining  a  product

’s 

eligibility  for  coverage  under  warranty.    If  returning  for  consideration  of  credit,  all  accessories  and 
documentation,  original  protective  material  and  cartons  must  be  included  and  the  equipment,  packing 
and  carton  must  be  in  new  resalable  condition.  Credit  for  returned  merchandise  will  be  issued  at  the 
lowest  current  price  and  is  subject  to  a  restocking  fee.    No  returns  accepted  on  discontinued  items.  
Techni-Lux is not responsible for  merchandise damaged in transit and reserves the right  to refuse any 
return  that  is  damaged  by  the  carrier,  not  accompanied  by  a  Return  Authorization  Number  (RMA#)  or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 

 

Model Number:  

TH-SCLPM20WW/B, TH-SCLPM20QW/B or TH-SCLPM20QA/B 

 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 
 

www.Techni-Lux.com

 

Содержание TH-SCLPM20QA/B

Страница 1: ...SCULPT 20 LED Profile Mini LED Ellipsoidal Information specifically for TH SCLPM20WW B TH SCLPM20QW B TH SCLPM20QA B V2 0 This manual contains important information Please read before operating fixtur...

Страница 2: ...not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux...

Страница 3: ...ons 9 TH SCLPM20WW Menu Settings 9 TH SCLPM20QW or QA Menu Settings 9 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapters for 3 or 5 pin XLR 11 DMX Start Address 11 DMX Channel Assig...

Страница 4: ...e 5 to 113 F 20 to 45 C Min distance to flammable surface 3 3 ft 1 0 m Min distance to illuminated surface 1 0 ft 0 3 m Electrical Voltage 12v DC Rated Power 22W Connection DC coaxial connector Rating...

Страница 5: ...ts received in non original packing and or cartons Purpose of Manual The purpose of this manual is to explain the necessary steps for using this fixture properly and to assure peak performance of said...

Страница 6: ...rientation provided appropriate clamp is used to mount securely Secure all cables properly and keep away from hot surfaces to prevent heat damage and trip hazards Do not obstruct any vents 1 LED Displ...

Страница 7: ...hoose the orientation that puts the Color Frame Locking Clip is in the most up position to prevent color frames from accidentally falling when unlocked 3 Reinstall Focus Knobs adjust lens back and for...

Страница 8: ...ring Diagrams There are two basic ways to use the fixture One is in standalone which does not require the use of any data lines to be connected nor any controller each fixture would operate independen...

Страница 9: ...o Scenes two demo looks to choose from when no DMX control Master mAst On off Master Mode default is Off When On unit outputs the current settings MENU Display Options Description Address A001 r001 51...

Страница 10: ...ress In this case the fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address without concern for the order they are con...

Страница 11: ...ddresses Example Select Start Addresses for 4 fixtures each requiring 2 channels of DMX For this example start with the first unit set to the first possible Start Address 1 This fixture occupies DMX c...

Страница 12: ...ect 4 Macro Speed 000 255 Rainbow speed 5 Red 000 255 Red Intensity Level 0 100 6 Green 000 255 Green Intensity Level 0 100 7 Blue 000 255 Blue Intensity Level 0 100 8 White 000 255 White Intensity Le...

Страница 13: ...to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and...

Страница 14: ...rent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receivin...

Страница 15: ...Block Adaptor CA XLR5 5 5 DMX 5 pin XLR Cable CA XLR5 10 10 DMX 5 pin XLR Cable CA XLR5 15 15 DMX 5 pin XLR Cable CA XLR5 25 25 DMX 5 pin XLR Cable CO XLRTERM3 XLR 3 Pin Data Terminator CO XLRTERM5 XL...

Страница 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...

Отзывы: