background image

 
 

 

 

           

 

 

  
 
 
 
 
 
 
 
 
 
 

Information specifically for:

 

 

 DL-PANEL1-192U 
 

 

 

 

 

 

 

 

 

 

V1 

This manual contains important information.

Please read before operating fixture.

Содержание DL-PANEL1-192U

Страница 1: ...Information specifically for DL PANEL1 192U V1 This manual contains important information Please read before operating fixture...

Страница 2: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Страница 3: ...ration Modes 6 Stand Alone Mode 6 DMX Controlling Mode 7 DMX 512 Control 7 DMX Data Connection 7 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 8 DMX Channel Assignment 9 CH 1 Dimmer 9 CH 2...

Страница 4: ...7 x 3 62 Weight 4 5 lbs 2 0 kgs Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Vol...

Страница 5: ...pping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer wi...

Страница 6: ...ode is selectable by setting the dip switch combination from the information below The DMX mode requires data interconnect cables and a controller to be used The stand alone mode does not require any...

Страница 7: ...more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 2 channels of DMX if set to a Start Address of 7 it would use da...

Страница 8: ...ssible from the selected start address which does not cause a negative number Continue this process until zero is reached always subtracting the largest possible value that does not cause a negative E...

Страница 9: ...3 2 5 and occupy channels 5 thru 6 The last fixture is addressed 5 2 7 and will occupy channels 7 thru 8 Thus 4 fixtures using 2 channels each have Start Addresses of 1 3 5 and 7 and the next free cha...

Страница 10: ...optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory It...

Страница 11: ...s are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as...

Отзывы: