5.7 Test the Optical Output Signal
After the input signal confirmation, the optical power of the optical output port should be tested. Use the optical power
meter to test the output levels; the output values should be in accordance with the technical specifications.
Before testing, the testing tools must be calibrated. For optical signals verify the interfaces are clean and not damaged.
CAUTION!
The device output optical power measurement procedure and regular maintenance must be performed
by highly trained personnel. In any case, they must be aware of and comply with the following warnings
associated with FT5S optical transmitter module:
WARNING
Module emits an invisible laser when working. Avoid direct contact with laser connector. Do not look
directly at the fibre connector.