Model: TX-203,TX-204,TX-228; Article No. 5021,5023,5040; 10/2022 

Note 

 In principle, the installation should only be carried out by qualified personnel. For 

installations of more than 600 W, the installation must be carried out by a specialist 
electrical company! Please also observe the requirements of your network operator 
and local legal regulations.

 Only use the product for purposes due to its intended 

function 

 Do not damage the product. Following cases may damage the product: 

Incorrect  voltage,  accidents  (including  liquid  or  moisture),  misuse  or  abuse  of  the 
product, faulty or improper installation, mains supply problems including power spikes 
or lightning damage, infestation by insects, tampering or modification of the product 
by persons other than authorized service personnel, exposure to abnormally corrosive 
materials,  insertion  of  foreign  objects  into  the  unit,  used  with  accessories  not 
preapproved. 

 Refer to and heed all warnings, precautions and safety instructions 

in the user manual. 
 

Safety instructions 

  Read  the  user  manual  carefully. They  contain  important  information  on  the  use, 

safety and maintenance of the device. Keep the user manual in a safe place and pass 
them on to subsequent users if necessary.  

 Before installing or using the Solar Balcony Power Plant, please read all instructions 

and warnings in the technical documentation, on the microinverter and on the solar 
modules. 

 The device may only be used for its intended purpose in accordance with this user 

manual. 

 Observe the safety instructions during use. 

  Before  commissioning,  check  the  device  and  its  connecting  cable  as  well  as 

accessories for damage. Do not use the device if it shows visible damage. 

 Operate the device only from household power sources. Check whether the mains 

voltage specified on the type plate corresponds to that of your mains supply. 

  Perform  all  electrical  installations  in  accordance  with  local  regulations  (including 

VDE).  

 When installing and operating the plug-in photovoltaic system, observe the national 

legal regulations and the connection conditions of the grid operator. 
In particular, DIN VDE V 0100-551-1 (VDE V 0100-551-1), VDE AR-N 4105:2018-11, 
DIN VDE 0100-712, DIN VDE 0100-410 and DIN VDE V 0628-1 (VDE V 0628-1). 

 Note the information on determining the line reserve at the end of these operating 

instructions. 

  Note  that  the  housing  of  the  micro  inverter  is  a  heat  sink  and  can  reach  a 

temperature  of  80  degrees  Celsius.  To  reduce  the  risk  of  burns,  do  not  touch  the 
housing of the micro inverter. 

 Do not squeeze the power cord, do not pull it over sharp edges or hot surfaces; do 

not use the power cord for carrying. 

 If the power cord of this device is damaged, it must be replaced by the manufacturer 

or its customer service or a similarly qualified person in order to avoid hazards. 

 The appliance is intended for household or similar use only. It must not be used for 

commercial purposes! 

Содержание TX-212

Страница 1: ...physical sensory or mental capacities or by persons lacking in experience or knowledge unless they are supervised or instructed on the use of this device by a person responsible for their safety Chil...

Страница 2: ...on 9 Requirements for the operation of a photovoltaic system 9 Connecting the micro inverter 9 Mounting 11 General hints 11 Balcony 11 Flat roof bitumen roof 11 Facade 12 Connect the solar panels DC c...

Страница 3: ...Specifications subject to change without notice please make sure you are using the latest manual available on the manufacturer s website ATTENTION According to the German Federal Network Agency instal...

Страница 4: ...ion on the microinverter and on the solar modules The device may only be used for its intended purpose in accordance with this user manual Observe the safety instructions during use Before commissioni...

Страница 5: ...n a low height Keep the product away from extreme heat Never immerse the product in water or other liquids Technical changes and errors excepted Warning Do not install the device if the AC cable of th...

Страница 6: ...ss and have received confirmation approval from the electricity network operator If you mount the micro inverters at a great height avoid possible fall risks Do not insert electrically conductive part...

Страница 7: ...able responsible for any direct indirect punitive incidental special consequential danger to property or life improper storage whatsoever arising out of or connected with the use or misuse of their pr...

Страница 8: ...r 1x AC input end cap 1x connection cable 1x user manual Prduct overview PV Micro Inverter 300W TX 203 1 Betteri socket input 230V AC 4 Betteri plug output 230V AC 2 Mounting hole 5 Input solar panel...

Страница 9: ...ement required A bi directional meter must be present or depending on what your electricity provider specifies Simple electricity meters are often not sufficient If necessary the consent of the landlo...

Страница 10: ...breaker but keeping the protective grounding conductor in the branch circuit breaker connected to the micro inverter Then disconnect the DC inputs CAUTION Do not under any circumstances connect the DC...

Страница 11: ...he photovoltaic system can be installed up to a roof height of 9m a sea level of max 350 m and a roof pitch of 45 We recommend a distance of 1 25 m to fire walls of adjacent buildings e g row houses F...

Страница 12: ...The connectors of some solar panels have the polarity printed on them which is valid for the panels The DC cable of the micro inverter with the plus marking is connected to the pole of the panel the n...

Страница 13: ...need to produce at least a start voltage of 22V Initial state 1 The micro inverter is connected to the solar panels 2 The microinverter is connected to the house mains via Wieland plug recommended or...

Страница 14: ...d grid exceeds falls below the voltage frequency range of the micro inverter If the LED shows no function or remains OFF the most common cause is that there is no connection to the solar panel or the...

Страница 15: ...the equipment or cause electrostatic charges Avoid temporary repairs All repairs should be made only with original spare parts Each micro inverter should be protected by a circuit breaker but central...

Страница 16: ...under 50Hz 220 V 230 V 55 65 under 60Hz 220 V 230 V Power factor 0 99 standard 0 8 leading 0 8 delayed Output current harmonic distortion 3 Maximum number of devices in series 12 6 Efficiency safety a...

Страница 17: ...overloading of the cables in the household they are protected by a line circuit breaker LSS This switches off automatically as soon as an overload occurs As a rule several sockets and consumers are pr...

Страница 18: ...16A circuit breaker 0 5 1 5 5 7 Maximum rated current Ig of the power generation system with 13A circuit breaker 3 5 4 5 8 10 Photovoltaic system one solar module two solar modules up to 3 115W from...

Страница 19: ...5W In the example right half of the picture the power of the mini solar system is 2 6A 600W which complies with the permissible load Further safety instructions Only connect the mini solar system to a...

Страница 20: ...of old devices that can no longer be used separately from household waste e g at a collection point in his or her municipality or district This ensures that the old devices are properly recycled and t...

Отзывы: