8
Model: TX-201/202 Article No. 5010/5011, 08/2022
.
In low temperature environment, battery charging failure:
When -10+/-3 , the battery is under low temperature protection, the icons
1, 2, and 3 are displayed at the same time, and the icon 3 is flashing,
Recovery temperature after charging low temperature protection: 0+/-3 .
High temperature environment, battery discharge failure:
When the temperature is 60+/-3 , the battery is protected against high
temperature level I, and the icons 1, 2, and 3 are displayed at the same time,
When the temperature is 65+/-3 , the battery is protected against high
temperature level II, and the LCD screen will hold the breath without any
display. At the same time, the red light on the AC switch button flashes,
Recovery temperature after discharge high temperature protection: 55+/-3
.
Battery charging failure in high temperature environment
When the temperature is 60+/-3 , the battery is protected against high
temperature, the icons 1, 2, and 3 are displayed at the same time, and the
icon 3 is flashing, Recovery temperature after charging high temperature
protection: 50+/-3 .
4
Time required to fully charge the battery
Battery life time
5
Fan icon (appears when the fan is working)
6~9
Figure 6: Battery level display (about 10% per grid);
When charging, the bar corresponding to the battery will flash; if the
battery shows 0%, the Figure 6 will flash.
Figure 7: Battery charging icon (appears while charging)
Figure 8: Battery charging power (appears while charging
Figure 9: Battery Percentage
10~12
Figure 10: Energy Storage Power Specifications (Inverter Power
Figure 11: Appears when the DC switch is open, flashes when overloaded
or short-circuited,
Figure 12: Appears when the AC switch is turned on, and flashes when
there is a fault (Including: short circuit, overload, under voltage, over
voltage, over temperature, etc.)
13~15
Figure 13: Display of total load power (about 10% per grid
Figure 14: Total load power (sum of all loads, including: AC, USB-A, TYPE-C,
DC, LED lights
Figure 15: AC output voltage
When the unit is charged and under load at the same time, it may
happen that the display shows unreasonable values on input and output
Display, e.g. if the unit get charged with a power of 100W and