1
Safegua
rds
2
Terms and
Warranty
3
Principl
e o
f
Operati
on
4
Ins
talla
tion
5
Operati
on
6
C
ont
rol Syst
em
7
RF Componen
ts
8
Power
Supp
ly
9
Maintenan
ce
10
Troubleshoo
ting
The model number and serial number of the unit are displayed in the top left
of the browser screen.
The Status Flags section provides the user with feedback from the system.
Specifically, there are status flags for:
RF Carrier is on or off
Forward RF in Overdrive (>110% Full Scale (FS) )
High VSWR
Pallet Voltage Supply Good
RF In Level Good
High
Temperature
The Performance section provides the user with specific parameters and
measurements in the system. Measurements that can be viewed from the
Performance box are:
Forward RF Levels as a % of Full Scale (FS)
Reflected RF Levels as a % of FS
DC Supply Voltage in volts
Temperature in °C
Current of pallet(s) in Adc
VSWR Trip Point Limit
AGC measured against 100% FS
Deviation
Right Level/Left Level input attenuation
Frequency in MHz
Pre-Emphasis, selectable between 0, 25, 50, or 75 us