BK Mikro 7 Manual
OI: BK MIKRO 7
Page 34
Rev. 2.00 dated 20.01.2006
7
Cycle Times
Scanning times
The following
cycle times
hold for systems with scanner BK7SC or BK7RLSC:
"Intensity"
BK7SC – Scanning in one direction
BK7RLSC – Scanning in both
direction
Switch
Angle
"Teach"
"Start"
Angle
"Teach"
"Start"
15°
210 ms
150 ms
±15°
320 ms
260 ms
15°
170 ms
120 ms
±15°
210 ms
190 ms
90°
580 ms
280 ms
±45°
720 ms
370 ms
90°
330 ms
250 ms
±45°
360 ms
300 ms
180°
1000 ms
390 ms
±90°
1200 ms
470 ms
180°
520 ms
370 ms
±90°
550 ms
410 ms
270°
1440 ms
510 ms
±180°
2400 ms
720 ms
270°
700 ms
470 ms
±180°
1100 ms
630 ms
Note:
"Cycle" time means: wand returned to stop position.
"Measuring time" for "K.O." in a "Start" cycle
≈
½ cycle time
when using scanner BK7SC, i.e. for scanning in one direction.
Times hold for setting "Tolerance" switch to "small",
switch set to "great" will slightly increase "Start" cycle times!