NOTE If no sensor is connected to the Clima Micro
Plus Temp/Humidity Fan Control, the fan runs
continuously at the set minimum speed.
3. Connecting sensor
The minimum sensor required is the Temp/RH Sensor.
Always switch the controller off if you want to replace
the sensor.
4. Control and set the Clima Micro
Plus Temp/Humidity Fan Control
The Clima Micro Plus Temp/Humidity Fan Control has 3
rotary knobs to set the minimum fan speed, the desired
temperature level and the desired relative humidity.
This controller also allows you to set a hysteresis for
temperature and relative humidity, and a time delay for
switching between day and night mode.
4.1 Minimum fan speed
After installing the Clima Micro Plus Temp/Humidity Fan
Control the fan starts to run (the fan must be on). Set
the desired minimum fan speed “Min Fan Speed” (10% –
100%) by turning the left knob.
The display successively shows: current fan speed/set
minimum fan speed, current fan speed/day-night
programme, time delay.
4.2 Relative humidity
Turn the middle knob to set the desired relative
humidity level
“RH Set” (40% –
90%).
4.3 Temperature
Turn the right knob to set the desired room temperature
“Temp Set” (15 °C –
35 °C).
4.4 Hysteresis
During the start-up of the Clima Micro Plus
Temp/Humidity Fan Control you can set the hysteresis
for temperature (1 °C - 5 °C) and relative humidity (0%
–
5%). To do this, complete the following steps:
1.
Put the plug of the Clima Micro Plus Temp/Humidity
Fan Control into an electrical outlet. The next
screens are displayed:
2.
Put a precision screwdriver (or paper clip) in the
small round hole on the back of the Clima Micro
Plus Temp/Humidity Fan Control and press carefully
Temp 26c
Max 30c
Fan 66%
RH 45%
Set 50%
RH 45%
Hys 5%
RH 45%
Min 41%
RH 45%
Max 51%
Fan 68%
Fan 59%
Min 25%
Fan 59%
Day / night
Delay
2M
TechGrow