28
TS8200D Series
Micro-Meter Mix User Guide
-
Release the footswitch to stop the pump.
2.
Shut-off the air supply to the pumps.
3.
Stop fluid supplies to the pumps and disconnect fluid supply tubing.
4.
Unmount the TS8200D.
5.
Disconnect motor connections from the pump to the controller.
6.
Remove mixing nozzle.
5.2 Pump Disassembly
1.
Use a 2.0 mm hex wrench to remove the mixing nozzle adaptor.
2.
Use an 8
mm (5/16”) wrench or crescent wrench to
remove pressure sensors or use a flat head
screwdriver to remove manifold plugs. Replace plug
screw O-rings if damaged.
Tips:
-
The surface of the sensors is extremely sensitive. Therefore, take extra caution
when handling these sensors and avoid hitting them against other surfaces.
-
Label sensors such that the same sensor is mounted in the same location upon
reassembly
3.
Remove fluid inlet fitting.
4.
Use a Phillips #2 screwdriver to remove x4 vent screws and vent seal O-rings.
Replace O-rings if damaged.