12
TS8200D Series
Micro-Meter Mix User Guide
4. Installation
4.1 Out of the Box Assembly Instructions
Required tools:
-
8mm (5/16”) wrench or crescent
wrench or flat head screwdriver (for mounting
pressure sensors)
- 3.0 mm hex wrench (for manifold screws)
- 2.5 mm hex wrench (for mounting calibration adaptor)
- 2.0 mm hex wrench (for mounting K-type nozzle locking plate)
- Dispensing Fluid (material to be used or cleaning/lubricating fluids)
Warning!
Do not dry-assemble the rotor and stator. Excessive friction between dry
components may damage stators and effect pumps performance.
*
Do not use water.
Using water may damage the pump. Recommend using
conditioning fluid for cleaning.
1.
Apply the dispensing fluid or any appropriate lubricant compatible with the
dispensing fluid to the surface of the rotor.
2.
Wet the stator opening by squeezing a small amount of the dispensing fluid or
any appropriate lubricant that is compatible with the dispensing fluid.
3.
Screw the stator onto the rotor in a clockwise direction, align the 4 tabs of the
stator with the 4 notches of the stator housing, and push in the stator to lock it
into place with the stator housing.