![TECHCON TS8200D Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/techcon/ts8200d-series/ts8200d-series_user-manual_1066387020.webp)
20
TS8200D Series
Micro-Meter Mix User Guide
Note:
Purge Pump 1 icon will dispense the resin at a safe speed for initial priming of
the pump.
4.
Press the foot switch.
5.
Allow the fluid to flow from the manifold until a steady
stream of air free material is observed.
6.
Release the foot switch.
7.
We are now done purging pump 1.
iii.
To vent the resin:
1.
Have a cleaning towel or container under the pump ready
to catch material
2.
Using a Phillips head screwdriver, loosen front vent screw
by turning in the counterclockwise direction. Loosen screw
in 1 revolution increments. At around the 6
th
–
7
th
revolution,
you should begin to see material seep out. Allow material to
escape until no more air bubbles are observed.
Warning:
Do not loosen to more than 8 complete revolutions. Doing so will
unfasten the screw allowing pressurized material to spray out.
3.
Fasten the venting screw. Avoid over tightening the screw.
Over tightening may lead to tearing of the vent seal O-ring.
e.
Purging and Venting
“HARDENER”
–
Pump 2
i.
Place a clean towel or a container under the pump
Tip:
Never use the same cleaning towel for both process fluids. Mixing the fluids
may lead to undesired chemical reactions.