11
5.2.3
Spray Time setting
Note: A complete cycle consists of Pre-Spray, Spray and Post-Spray.
Pre-spray: Atomized air turned on before the valve is opened.
Post-spray: Atomized air stayed on after the valve is closed.
1.
Touch the “Pre” icon to setup pre-spray time
2.
Touch Up and Down arrows to set the desired pre-spray time
3.
Touch the Check Mark icon to save and exit
4.
Touch the “Post” icon to setup post-spray time
5.
Touch Up and Down arrows to set the desired post-spray time
6.
Touch the Check Mark icon to save and exit
5.2.4
Manual/Purge Cycle Setting
1.
Touch the Purge icon to select the purge cycle.
The Purge icon will turn to green color.
2.
Press and hold down the foot switch to activate the purge cycle.