8. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTION
Display does
not light up
No power inputs
Check power cord
connections
Turn on power
System will not
actuate
Supplied pressure
dropped below “Low
Pressure” setting
Foot switch not plugged
in or improperly
plugged in
Defective foot switch
Broken wire or loose
connection inside unit
Defective solenoid
Defective PC board
Increase supplied
pressure
Check foot switch
connection
Foot switch needs to be
repaired or replaced
Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
Replace solenoid
Replace PC board
System will not
pressurize
Insufficient air pressure
Air hoses not plugged
in
Regulator defective
Increase air supply
pressure
Check connection
Replace regulator
Inconsistent
dispense
Air bubbles in material
Dispense time is too
low
Needle clogged
De-air material
Increase dispense time
Replace needle