ULTRA CLEAN LUBRICATED COMPRESSOR
INSTALLATION
1.
ULTRA CLEAN LUBRICATED COMPRESSOR LOCATION REQUIREMENTS
The Ultra Clean Lubricated Compressor location should be level, accessible and well ventilated.
If the Ultra Clean Lubricated Compressor will be located in a confined space, provide adequate ventilation.
Electrical
(1) Line voltage must be within the limits of Figure 1 below. (Install a “buck-boost
transformer” if line voltage is not between these values.) Circuit breaker switches
must be 20 - 30 amp depending on model and voltage necessary.
(2)
Local code may require you to provide one quick disconnect (safety switch) for the
compressor.
(3)
See Figure 1 below for breaker size and line voltage.
CAUTION - Voltage must be 110/128 v or motor damage may occur.
CAUTION - Voltage must be 208/240 v or motor damage may occur.
3
Figure 1: Recommended Wire and Breaker Size
Single Head Compressors
Model
Voltage
Amperage
Wire Size
Recommended
(Gauge)
Breaker Size
ACL2S2
230
7.2
12
20
ACL2S1
115
13.6
12
20
ACL4D2
230
14.4
12
20
ACL6T2
230
21.6
10
30
Dual Head Compressors
Triple Head Compressors