38
TECH RS regulator
Select this option if you connect a room regulator with RS communication. Such a regulator enables the user
to view current CH boiler parameters and change certain settings e.g. pre‐set CH boiler temperature, pre‐set
DHW temperature.
Standard regulator
Select this option if you connect a two‐state regulator. Such a regulator sends a signal to the main controller
informing if the pre‐set room temperature has been reached or not.
CH pump room regulator
When this option is selected, the signal from room regulator informing that the pre‐set room temperature has
been reached disables the CH pump.
Room reg. temp. lower
NOTE
This parameter concerns
RS regulator ‐ decrease
function and Standard regulator and TECH regulator
with RS communication.
The user sets the value of pre‐set valve temperature reduction which will be introduced when the pre‐set room
temperature is reached.
The temperature reduction will not be lower than the minimum pre‐set CH temperature.
Example:
Pre‐set CH boiler temperature
55°C
Room reg. temp. lower
15°C
Minimum pre‐set CH boiler temperature
45°C
Pre‐set CH boiler temperature after the pre‐set temperature
value has been reached
45°C
Once the pre‐set room temperature has been reached in the building (signalised by the room
regulator), the pre‐set temperature at the CH boiler will be reduced to 45°C (10°C difference) although
the value of
Room reg. temp. lower
parameter is 15°C.
4.4.10
Fuel level calibration
FITTER'S
MENU
F
UEL
LEVEL
CALIBRATION
Fuel tank full
Fuel tank empty
Conducting fuel level calibration properly enables the user to view the current level of fuel on the controller
screen.
The first step involves filling the fuel tank up
Next, select the option
Fuel tank full.
The controller
remembers the level as full (100%).
When there is no fuel left in the tank (after a period of CH boiler operation), select the option
Fuel
tank empty
.