16
Operation modes – Tap on this icon to choose one of the following pump operation modes (in the CH boiler
controller): House heating, Water tank priority, Parallel pumps or Summer mode. Detailed description of
particular operation modes may be found in the CH boiler controller manual.
C)
INSTALLATION CONTROLLER SUBMENU
Operation modes – Tap on this icon to choose one of the following pump operation modes (in the CH boiler
controller): House heating, Water tank priority, Parallel pumps or Summer mode. Detailed description of
particular operation modes may be found in the CH boiler controller manual.
7.
LANGUAGE VERSION
Tap on this icon to select the language version of the menu.
8.
SOFTWARE VERSION
After selecting this icon, the display shows the CH boiler manufacturer's logo as well as the information about software
version.
9.
SETTINGS
Tap on this icon to configure additional parameters.
Temperature sensor – Tap on this icon to configure the hysteresis and calibration of room regulator temperature
sensor.
o
Hysteresis – This function is used to define tolerance of the pre-set temperature in order to prevent undesired
oscillation in case of small temperature fluctuation (within the range 0 ÷ 10⁰C) with the accuracy of 0,1°C.
Example: if the pre-set temperature is 23⁰C and the hysteresis is 1⁰C, the room temperature is considered too
low when it drops to 22⁰C.
o
Calibration – Calibration should be performed while mounting or after the regulator has been used for a long
time, if the room temperature measured by the sensor differs from the actual temperature. Calibration setting
range is from -10
O
C to +10
O
C with the accuracy of 0,1
O
C.
Type of main controller – Tap on this icon to select the type of the main controller to cooperate with the room
regulator: standard controller, pellet controller or installation controller. CH boiler control submenu will change
accordingly.
Built -in clock – date and time will be automatically downloaded from the panel, and then it will be displayed on
the main screen even if communication with the main controller is interrupted.
Software update – this function enables the user to update the controller software using a USB flash drive.
Wireless communication – the function enables the user to activate wireless communication and select the
communication channel. ‘37’ is the default channel. If no radio signals interfere with the operation of the device,
it is not necessary to change the channel.