16
44 1657 101-H
TankQuick eco
TankQuick eco
TankQuick eco
TankQuick eco
6.8
6.8
6.8
6.8
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Fault
Possible cause
Action
Pump does not start
Compressed air not connected
Connect the compressed air
supply and check the input
pressure
Start button not pressed
The start button must be kept
pressed during operation
Operating pressure too low –
input pressure to low
The input pressure is of < 2 bar
Check the adjustment of the
pressure regulator of the air
supply and switch to a higher
input pressure
Low or no pumping
capacity
Wrong pumping direction
Connect the delivery hoses
according to the desired mode
of operation (chapter 5)
Difficult operating conditions
The pumping capacity is limited
when extracting through
winding filler pipes and with
small suction hose cross-
sections.
Operating pressure too low –
input pressure of the compressed
air supply too low
Check the input pressure of the
compressed air supply, the
input pressure must exceed the
desired operating pressure.
Leak in the compressed air
system
Examine the compressed air
system for leaks, clean and
replace damaged parts if
necessary
Dirt trap in the compressed air
system is dirty
Remove the dirt trap from the
pressure regulator and clean it
(chapter 6.3)
Silencer on the pump is dirty
Clean the silencer
Dirt trap in the delivery system is
dirty
Remove the sieve from the dirt
trap and clean it (chapter 6.3)
Suction line kinked or damaged
Check the fuel suction/refilling
line for possible damage
Service life of the wearing parts
of the pump exceeded
Return the pump for overhaul