![TEC Prizrak-810 BT Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/tec/prizrak-810-bt/prizrak-810-bt_technical-description_4027991023.webp)
23
TEC-67231-2 Technical description Prizrak-8xx BT
28
Pulse for driver’s door
opening imitation
A 1,5 sec. duration pulse is generated which imitates that a vehicle’s owner is getting out of the car. For
ACC turning off after remote start mode operation is terminated
29
Trunk release pulse
A pulse of 0,8 sec. duration is generated. It is necessary to assign any alarm digital output to be able
to unlcok the trunck via the app or GSM menu
30
A third party remote engine
start module control
A constant level signal is generated from the moment of engine start and until the ignition is turned off.
The signal is generated regardless of using the ESM-250 module; regardless of connection settings to
ignition switch or to Start/stop button. The feature will start functioning only after it is assigned to a
digital output, and only after that the remote starter programming menu will be available as well as the
remote starter control commands and smart voice menu settings
31
Gas pedal locking (NC relay
control)
Is designed for vehicle immobilization when the AntiHiJack is triggered, while taking into account «Safe
engine locking mode» settings
32
Pulse to latch pin door
blockers
A pulse of 0,8 sec. duration is generated to latch aftermarket pin doors blockers
33
Pulse to unlatch pin doors
blockers
A pulse of 0,8 sec. duration is generated to unlatch aftermarket pin doors blockers
34
Normally open relay control
for CDL unlocking blockage
The alarm generates a signal on the output after receiving the unlocking command from the OEM
remote and detecting a tag. The signal will be generated until the system is armed. The signal is generated
constantly when CAN-bus is active; when service mode is turned ON or if the authentication method
has been changed to «PIN code»
35
Double wire status control
Fortin/iDataLink — «GWR»
The features operate simultaneously. Аre used for remote starter Fortin module control. If these
functions have been assigned to programmable outputs — it will be impossible to use ESM-250
module and the functions №37, №38, №39. In order to be able to use ESM-250 module and the
features №37, №38, №39 — re-programme the outputs to any other features
36
Double wire status control
Fortin iDataLink — «Start»
37
Steering wheel unlock control
(remote start for Toyota/Lexus) Is used for remote engine start on certain Toyota/Lexus vehicles, (refer to the Integrator)
38
—
—
39
40
Single wire pulse control
Fortin/ iDataLink
Is used for Fortin/iDataLink modules control
41
Engine heater status via LED
indicator
In case if an engine heater (OEM heater or aftermarket one) has been started via Prizrak (TEC) system by
any means then the LED will be glowing (if the LED output activated) while the engine heater is functioning
42
Dashcam control
A signal is generated: when the ignition is ON; within 5 minutes after the alarm is triggered (warning
or panic); If panic is triggered via smartphone. If the alarm has been triggered or panic activated via
smartphone repeatedly then a DVR operation will be extended for 5 minutes more
43
Heating control during remote
start mode operation (status
control)
In 30 seconds after the engine has been started with remote start system — a constant level signal is
generated on the outputput. The signal will remain active until the remote start mode is terminated. Is
used for activation of heated mirrors, seats, steering wheel, rear window heating and etc
44
Normally closed relay control
for vehicle’s CDL unlocking
blockage
The output generates a constant level signal while the car is armed. As soon as the alarm receives the
unlocking command from the original remote key or keyless entry system and detects a tag, the output
stops generating the signal
45
Service (valet) mode status
A constant level signal is present on the output while the system is in service (valet) mode
46
Heating control in the remote
engine start mode (pulse
control)
In 30 sec. after the engine has been remote started: one, two or three pulses are generated (depending
on the settings). It is used for side mirrors, seats, steering wheel, rear window heating activation. The
pulses for heating deactivation are not generated
47
Remote engine start status
The output generates a constant level signal while the remote start is running
48
Starter control (remote engine
start for specific vehicles)
It is used when implementing the remote engine start feature on particular cars
49
«Ignition» control. (remote
engine start for specific
vehicles)
It is used when implementing the remote engine start feature on particular cars
50
Output for the remote start.
The feature is assigned to suit
individual needs
Refer to the «Feature
№50 programming
algorithm «Remote start output», page 25
51
Hazard lights alternative
control
A programmable output with the assigned feature «Hazard lights alternative control». It is designed for
controlling the vehicle’s hazard lights when there is no control over the CAN-bus. The output should be
connected to the wire harness of the hazard lights button. It is configured automatically after interfacing
the alarm with a vehicle, But may be adjusted manually if needed
52
CDL alternative control. Pulse
to «Lock» for double wire
control or pulse to lock/unlock
for single wire control
It is used if there is no contrlol over CDL via CAN-bus. The output is assigned automatically after the
alarm interfacing with a vehicle, but may be adjusted manually if needed
53
CDL alternative control.
«Unlock» command for double
wire control
It is used when there is no control over CDL via CAN-bus. The output is assigned automatically after
the alarm interfacing with a vehicle, but may be adjusted manually if needed
54
Wired engine lockig by
controlling a NO or NC relay
The output is used for NO or NC relay control. The output operation is dependant on a selected operation
algoroithm — «Wired engine locking type». The default setting is: NC engine locking.control
55
Panic/Warning
signals to the siren
The output designed for syren control.
The output №8 (24 pin)
56
Engine heater circulation pump
control
The output generates a constant level signal while the engine heater is running and within two minutes
after turning OFF the ignition
57
Engine blocking by imitating
the start/stop button push
Refer to the chapter: «Engine blocking by imitating the Start/Stop button push»
58
An external beeper control
A signal on the output is formed according to the embadded beeper operation algorithm. When this
feature is assigned to any programmable output the embadded beeper stops working
59
Programmable logic output
A signal is formed according to an operating algorithm developed in the «Programming studio»
*
Any gear lever position allowing to drive forward (D, S, M ,L and etc.).