FanControl‑GSM v2
9
Table 4. List of SMS‑commands
List of SMS commands
Code
Parameter
Commands to control launches
Turn on heater/Extend heater runtime
832
–
Turn off heater
833
–
Turn on /extend runtime of ventillation system
837
–
Turn off ventillation system
838
–
Requests
Receive account balance
842
–
Receive vehicle’s location
843
–
”
Vacation mode
“
(turn on/turn off)
All launches, notifications, and task manager
852
On/Off
All launches
853
On/Off
All notifications
855
On/Off
All tasks
857
On/Off
Table 5. System setup
Menu
Menu
code
Factory
default Note
Protocol
W‑BUS/Eberspächer
6
1
Set automatically. Choose by hand if required.
1 – Automatic identification; 2 – Webasto;
3 – Eberspächer;
4 – Protocol control is forbidden;
5 – Factory Webasto heater alternative protocol
for VAG;
6 – Factory Webasto heater for RR Evoque (2011‑
2013);
7 – Factory Eberspächer for RR Evoque (2011‑
2013)/Sport (2014‑2015);
8 – Factory Eberspächer for Toyota;
9 – Factory Eberspächer for RR Sport (2016)
The vehicle battery voltage
level for automaic system
shut down
11
9
1 — 10,5 V; … 9 — 11,3 V; ... 11 — 11,5 V
Heater operation time
10
3
1–10 min; 2–20 min; 3–30 min; … 12–120 min
Ventillation
system
operation time
12
4
1 — off; 2 — 10 min; 3 — 20 min;
4 — 30 min
Preheater mode
14
2
If outside temperature is lower 5°C — an
aftermarket heater will start automatically. If
outside temperature increases to 12°C — heater
will turn off.
1 — on; 2 — off
Climat
sytem
control
algorithm
16
1
1 — standard
;
2 — alternate algorithm №1
*
;
3 — alternate algorithm №2
*
;
4 — alternate algorithm №3
*
Aftermarket
heater temperature limiter
*
15
1
1 — disabled; 2 — 71°C; 3 — 73°C; … 9 — 85°C
Optional
temperature
sensor №1
**
18
1
1 — engine
temperature;
2 — outside
temperature; 3 — interior temperature
Optional
temperature
sensor №2
**
20
3
1 — engine
temperature;
2 — outside
temperature; 3 — interior temperature
Climate control setup
*
22
1
1 — enabled; 2 — disabled
Содержание FanControl-GSM v2