System control

You may control the system by means shown in figure 4.

Via smart voice menu

Via SMS

With smartphone application 

FanControl for iOS and Android 

Via factory remote control

Setup by calendar

Setup by timer

Figure 4. Means to control the system

  System control:  

1. 

Via mobile phone.

 You may access all features via mobile phone: for example turn off anf turn 

on the heater, check state and location of the vehicle, adjust system settings. You may control it 

with intellectual voice menu or smartphone application, and via SMS (see table 4). 

2. 

Via one of the vehicle’s buttons.

 Turn on/off by long (at least 2 seconds) push on a designated 

button ( see www.tecel.ru/en/).

3. 

Via remote control. 

Turn on the heater by pressing   3 times. Turn off by pressing   3 times. 

pause between button presses should be ~3 s.

4. 

Via extenal inputs and additional devices. 

See figure 5 for control algorithms.

 Status control

*

12V
0V
Оn
Off

Input №18

FanControl

To restart the system via input № 18‑ the «satus signal» on the input has to disappear and  then appear again.

   

 

Trigger control

12V
0V

Input №15

FanControl

On
Off

Figure 5. Control algorithms via inputs

 SMS control 

Send an SMS containing command in following format: 

Access code*Command code#Parameter

”Access code“ — System access code.

”Command code“ — Same command code as in voice menu.

”Parameter“ — Is used in specific cases for certain commands.

Содержание FanControl-GSM v2

Страница 1: ...www tecel ru FanControl GSM v2...

Страница 2: ...via a phone vehicle factory remote or one of the vehicle factory buttons Heater control Control of the ventilation system for interior heating and windshield defrosting Vehicle state information facto...

Страница 3: ...70 unit 5 Activation of ventillation system in default mode 6 Usage of an aftermarket heater as a preheater 7 Climate control setup 8 Two temperature sensors coming with the system have to be connecte...

Страница 4: ...004 Leon 2006 Skoda Octavia 2 Octavia 3 Superb 2009 Toyota Auris 2007 Avensis 2009 Camry 2006 2011 Camry 2012 Corolla 2014 Corolla 2006 2013 Highlander 2011 2013 Highlander 2014 Hilux 2006 2009 Land C...

Страница 5: ...ter is running 150 12 Black Power Ground 13 Yellow Black TP BUS Digital bus to connect GPS GLONASS 270 14 16 17 Blue In External control Trigger negative control 18 Pink Black In External control Stat...

Страница 6: ...heater mode For this mode outside temperature data is required system can receive in via CAN bus or via optional sensor 3 If the owner is planning to use automatic heater deactivation by temperature a...

Страница 7: ...as done correctly green LED will flash 4 times will show group subgroup if it was set and will stay lit 3 Enter group number Press PB corresponding number of times After a short pause 1 5 s green LED...

Страница 8: ...s buttons Turn on off by long at least 2 seconds push on a designated button see www tecel ru en 3 Via remote control Turn on the heater by pressing 3 times Turn off by pressing 3 times pause between...

Страница 9: ...1 2013 7 Factory Ebersp cher for RR Evoque 2011 2013 Sport 2014 2015 8 Factory Ebersp cher for Toyota 9 Factory Ebersp cher for RR Sport 2016 The vehicle battery voltage level for automaic system shut...

Страница 10: ...the manufacturer Output settings 23 38 Used only in special cases Check documentation to see which vehicles require these settings www tecel ru en Sensor is installed if there is no data in the CAN b...

Страница 11: ...FanControl GSM v2 11 Table 7 Package Name Amount pcs Main unit 1 Wire harness 1 Temperature sensor 2 Enclosure TEC 0500 1 Manual 1 Package 1...

Страница 12: ...tem support Turn on Turn off the heater Request vehicle coordinates Request account balance Vehicle with heater and ventillation system support without GPS GLONASS 270 Turn on Turn off the heater Turn...

Страница 13: ...equest vehicle s location Request SMS with access code Turn on Turn off vacation mode Turn on Turn off all launches notifications and task manager Turn on Turn off all launches Turn on Turn off all no...

Страница 14: ...current climate system parameters Online data unit setup Add message to the unit Remove message to the unit List to the unit s contents Set up quick access commands Set new command Launches Turn on Tu...

Страница 15: ...tion of all notifications with the STAR button Reach out mode setup Additional parameters setup Date and time Date Time Cellular network parameters USSD code to request account balance Rule to forward...

Отзывы: