Chapter 4 Pressure/Flow @ 50 and @ 25 Modes
4.1 Mode Summary
Mode
Application
Channel A Display
Channel B Display
Pressure/Flow @ 50 Pa
(PR/ FL @50)
Specialized mode for
one-point Blower
Door building
airtightness test.
Building pressure in Pascals.
Building leakage at 50 Pascals in units
chosen (CFM@50, m
3
/h@50, l/s@50,
in
2
@50, cm
2
@50).
Pressure/Flow @ 25 Pa
(PR/ FL @25)
Specialized mode for
one-point total
leakage duct
airtightness test.
Duct system pressure in Pascals.
Total duct leakage at 25 Pa in units
chosen (CFM@25, m
3
/h@25, l/s@25,
in
2
@25, cm
2
@25).
Note:
Appendix A
contains Quick Guides for using the DG-700 to conduct one-point building and duct system
airtightness tests using the
@50
and
@25
features.
4.2 Overview of Pressure/Flow @ 50 and @ 25 Modes
4.2.a Pressure/Flow @ 50 Mode:
The
Pressure/Flow @ 50
mode is used to conduct a one-point
Blower Door building airtightness test. In this mode,
Channel A
is used to measure building pressure while
Channel
B
is used to
display estimated building leakage at a test pressure of 50
Pascals. The leakage estimate shown on
Channel B
is
determined by mathematically adjusting the measured air flow
from the selected Blower Door fan using the real-time
Channel A
building pressure reading and a Can’t Reach
Pressure factor (see Section 4.8 below).
4.2.b Pressure/Flow @ 25 Mode:
The
Pressure/Flow @ 25
mode is a specialized mode used for
conducting a one-point total leakage duct airtightness test. In this
mode,
Channel A
is used to measure duct system pressure while
Channel
B
is used to display estimated total duct leakage at a
test pressure of 25 Pascals. The leakage estimate shown on
Channel B
is determined by mathematically adjusting the
measured air flow from the selected Duct Blaster fan using the real-time
Channel A
duct system pressure reading
and a Can’t Reach Pressure factor (see Section 4.8 below).
To select the
Pressure/Flow
@ 50
or
@ 25
modes, press the
MODE
button until the selected operating
mode shown o
n
the gauge display is
PR/ FL @50
or
PR/ FL @25
. When first entering either of these
two modes, the default pressure units on
Channel A
is Pascals, the default leakage units on
Channel B
is
CFM @ 50
or
25
, and the default time averaging period is
1 second average
.
14
Operating Instructions