background image

8

www.TEC-electronics.ru

TEC-63062-1 AutoCAN-Fv6

Table 3. Programmable Output Functions

Function

Description

1

Security

A constant level signal is formed for the time when the unit is in the Security 

mode

2

Increased Security

The function operation is similar to the Security function; however, the signal 

is formed prior to entering the PIN-code after disarming.

3

Arming Pulse

0.8-sec long pulse is formed when the controller enters the Security mode. 

4

Disarming Pulse

0.8-sec long pulse is formed when the controller exits the Security mode.

5

Pulse when entering 

PIN-code

0.8-sec long pulse is formed after entering the PIN-code.

6

Hood closing pulse

0.8-sec long pulse is formed when the controller enters the Security mode. If 

the hood is open, there is no pulse.

7

Pulse of trunk 

opening with factory 

remote control 

0.8-sec long pulse is formed when the controller detects the trunk opening 

command from the factory remote control.

8

Factory Alarm System 

Panic

A constant level signal is formed for the time while the factory alarm system 

(if installed) is in the Alert mode.

9

Siren Panic

A 30-sec long constant level signal is formed if one of the zones is triggered in 

the Security mode: trunk, doors, hood opening. This function can be used in 

the vehicles that are not equipped with the factory alarm system. The signal 

stops when the vehicle exits the Security mode.

10

Horn Panic

A 30-sec long pulse signal is formed if one of the zones is triggered in the 

Security mode: trunk, doors, hood opening. Also, it gives signals when arming/

disarming the vehicle. This function can be used in the vehicles that are not 

equipped with the factory alarm system. The signal stops when the vehicle 

exits the Security mode. It is used for Alert signal feeding to the vehicle 

factory horn.

11

Horn Panic from 

External Input

Apulse signal is formed for the time while there is an input signal to the 

external digital input with the Horn Control function.

12

Doors, hood and 

trunk

A constant level signal is formed if any of the preprogrammed doors, hood or 

trunk is open.

13

Sensors Ignoring

In the Security mode, a constant level signal is formed with the trunk open, if 

it has been opened using the factory remote control. Also, the signal is formed 

when the Comfort feature is active. This function is designed for organizing 

sensors deactivation to avoid false alarms.

14

Original buttons

A constant level signal is formed if a preprogrammed vehicle button is pressed.

15

Ignition

A constant level signal is formed with the ignition on (also when starting the 

engine).

16

ACC

A constant level signal is formed with the vehicle ACC on (first key position, 

in some vehicles may be congruent with ignition). This function is deactivated 

only when the key is removed from theignition lock. 

17

Engine is started

A constant level signal is formed with the engine started.

18

Engine rpm

A pulse signal is formed with a pulse sequence frequency proportional to the 

engine crankshaft rotational speed. 1 imp/sec corresponds to the crankshaft 

rotational shaft of 20 rpm. The signal is designed for determining estimated, 

and not the exact rpm value.

Содержание AutoCAN-F v6

Страница 1: ...www TEC electronics ru AutoCAN F v6 Technical manual...

Страница 2: ...or which the controller is designed along with its functional features information please refer to the Integrator program from www tec electronics ru Module Inputs Outputs For port contacts enumeratio...

Страница 3: ...and subgroup were assigned the controller shall be reset to the factory settings prior to interfacing Two interfacing options are available Automatic interfacing Upon connecting to the vehicle CAN bu...

Страница 4: ...nds 6 Enter the subgroup number by pressing the built in button the corresponding number of times Check correctness of the group and subgroup assignment by checking light signals group number pause su...

Страница 5: ...1 3 1 single wire pulse negative 2 single wire pulse positive 3 single wire pulse negative when Central Lock status is not available 7 Alternate Hazard Lights control algorithm via output no 2 1 5 1...

Страница 6: ...o 8 Parking Distance Control PDC system algorithm Activation on rear gear Front and rear parking sensors are activated upon shifting the transmission to R or with the control button and deactivated wh...

Страница 7: ...1 39 15 Ignition 10 Programmable output 20 1 39 12 Trunk 11 Programmable output 21 1 39 12 Hood 12 Programmable output 22 1 39 26 Handbrake 13 Programmable output 9 1 13 1 Activate Central Lock Comfo...

Страница 8: ...n the Security mode trunk doors hood opening Also it gives signals when arming disarming the vehicle This function can be used in the vehicles that are not equipped with the factory alarm system The s...

Страница 9: ...dal pressed 26 Handbrake A constant level signal is formed when the vehicle is put on the handbrake 27 External lights A constant level signal is formed with the external lights on 28 Timer Channel Co...

Страница 10: ...is used for managing the Parking Distance Control function with an external button 10 Hood control The function is used when information about the hood position is not available in the vehicle CAN bus...

Страница 11: ...signals and the doors will be assigned to this output If you do not press the brake pedal and exit current option programming the controller will save its previous condition Release the brake pedal a...

Страница 12: ...indicated in the output You shall stay on each seat for at least 2 seconds Press the brake pedal again The controller will inform about the option condition with series of 36 light signals If you do n...

Страница 13: ...1 second Make a pause of about 2 seconds between the digits In case you have made and error when entering the PIN code after about 3 seconds an audible signal is heard meaning that the PIN code shall...

Страница 14: ...lt in LED see Fig 2 The LED illuminates at the moment any of the below parameters are activated door opening brake pedal pressing etc and stays illuminated for 5 seconds or until this parameter is dea...

Страница 15: ...Data and Operating Conditions Characteristic Value Power supply voltage V 9 15 Max current consumption in operating mode mA 750 Max current consumption in standby mode mA 1 Operation temperature C 40...

Страница 16: ...16 www TEC electronics ru TEC 63062 1 AutoCAN Fv6...

Отзывы: