8
www.TEC-electronics.ru
TEC-63062-1 AutoCAN-Fv6
Table 3. Programmable Output Functions
№
Function
Description
1
Security
A constant level signal is formed for the time when the unit is in the Security
mode
2
Increased Security
The function operation is similar to the Security function; however, the signal
is formed prior to entering the PIN-code after disarming.
3
Arming Pulse
0.8-sec long pulse is formed when the controller enters the Security mode.
4
Disarming Pulse
0.8-sec long pulse is formed when the controller exits the Security mode.
5
Pulse when entering
PIN-code
0.8-sec long pulse is formed after entering the PIN-code.
6
Hood closing pulse
0.8-sec long pulse is formed when the controller enters the Security mode. If
the hood is open, there is no pulse.
7
Pulse of trunk
opening with factory
remote control
0.8-sec long pulse is formed when the controller detects the trunk opening
command from the factory remote control.
8
Factory Alarm System
Panic
A constant level signal is formed for the time while the factory alarm system
(if installed) is in the Alert mode.
9
Siren Panic
A 30-sec long constant level signal is formed if one of the zones is triggered in
the Security mode: trunk, doors, hood opening. This function can be used in
the vehicles that are not equipped with the factory alarm system. The signal
stops when the vehicle exits the Security mode.
10
Horn Panic
A 30-sec long pulse signal is formed if one of the zones is triggered in the
Security mode: trunk, doors, hood opening. Also, it gives signals when arming/
disarming the vehicle. This function can be used in the vehicles that are not
equipped with the factory alarm system. The signal stops when the vehicle
exits the Security mode. It is used for Alert signal feeding to the vehicle
factory horn.
11
Horn Panic from
External Input
Apulse signal is formed for the time while there is an input signal to the
external digital input with the Horn Control function.
12
Doors, hood and
trunk
A constant level signal is formed if any of the preprogrammed doors, hood or
trunk is open.
13
Sensors Ignoring
In the Security mode, a constant level signal is formed with the trunk open, if
it has been opened using the factory remote control. Also, the signal is formed
when the Comfort feature is active. This function is designed for organizing
sensors deactivation to avoid false alarms.
14
Original buttons
A constant level signal is formed if a preprogrammed vehicle button is pressed.
15
Ignition
A constant level signal is formed with the ignition on (also when starting the
engine).
16
ACC
A constant level signal is formed with the vehicle ACC on (first key position,
in some vehicles may be congruent with ignition). This function is deactivated
only when the key is removed from theignition lock.
17
Engine is started
A constant level signal is formed with the engine started.
18
Engine rpm
A pulse signal is formed with a pulse sequence frequency proportional to the
engine crankshaft rotational speed. 1 imp/sec corresponds to the crankshaft
rotational shaft of 20 rpm. The signal is designed for determining estimated,
and not the exact rpm value.