TEC Electronics CANTEC-F2 Скачать руководство пользователя страница 6

 

 

CAN-bus 

3.2.2.

 

Forced vehicle recognition 

Forced vehicle recognition is only to be executed in exceptional cases, when automatic 

vehicle recognition has failed. 

Programming is carried out via programming button and LED 

indicator, which are located in the unit’s body. Prior to forced 

vehicle recognition, the vehicle group previously 

must not

 

have been identified (if the vehicle group has previously 

already been identified, a factory reset is necessary) and the 

CAN-bus 

must not

 be connected. Programming stops if the 

programming button is not pressed within 60 seconds.  

Programming sequence 

of forced vehicle recognition: 

1.

 

Connect the unit to power only and wait for permanent short fast light signals. 

2.

 

Press and release the programming button 10 times (begin this action not later than 

10 seconds upon connecting the power source to the unit). If all the actions are 

carried out correctly, the unit confirms with three light signals. 

3.

 

Enter option No. 1 – forced vehicle recognition (see table 2, chapter 4.1.) – by 

pressing the programming button 1 time. The unit confirms the selection with 

repeated single light signals. 

4.

 

Enter vehicle group number by pressing the programming button for the 

corresponding number of times (see vehicle-specific installation file for group 

number). The unit periodically emits series of light signals, where the number of 

signals corresponds with the entered group number. 

5.

 

Wait at least 2 seconds. 

6.

 

Enter the vehicle sub-group number by pressing the programming button for the 

corresponding number of times (see vehicle-specific installation file for sub-group 

number). Check if the vehicle model has been chosen correctly. The unit emits light 

signals (group number – pause, sub-group number – pause): 

 

If the vehicle model is chosen correctly, press the programming button once. 

Light signals stop and the vehicle model is saved. 

 

If the vehicle model has been chosen incorrectly, press the programming 

button twice. Repeat the programming beginning from point 4. 

7.

 

Reconnect unit to CAN-bus. 

 

 

3.3.

 

Connections of programmable outputs/inputs 

After successful vehicle recognition disconnect the unit’s black-box from its harness. 

Connect all the input and output wires to the corresponding places. Make sure that 

unneeded output/input wires are isolated. 

Содержание CANTEC-F2

Страница 1: ...18 12 2019 CAN bus CAN bus interface CANTEC F2 CAN bus interface with USB support for analogue car alarms PDC more...

Страница 2: ...rogrammable output input configuration complete Product features CANTEC F2 is a universal CAN bus interface hereafter referred to as unit designed for connecting after market car alarm security park d...

Страница 3: ...which of the available programmable input and output functions are needed for the specific installation see chapter 4 2 Maximum currents of the unit s programmable inputs and outputs must match conne...

Страница 4: ...gnition 50 mA 7 Yellow red Programmable output PDC LED 50 mA 8 Green Programmable input PDC control button 1 5 mA 9 Blue Programmable input Unlock central door locking 1 5 mA 10 Brown red CAN high of...

Страница 5: ...ic vehicle recognition After installing the unit to power and CAN bus by carrying out a set of simple actions see vehicle specific installation file for procedure the vehicle specific group and sub gr...

Страница 6: ...button 1 time The unit confirms the selection with repeated single light signals 4 Enter vehicle group number by pressing the programming button for the corresponding number of times see vehicle spec...

Страница 7: ...ight signals There is no countdown until programming mode is deactivated 5 Change the option s setting value exception option no 9 PDC control button see table 2 instead by pressing the programming bu...

Страница 8: ...tial door opening disabled LED is on the function is on LED is off the function is off Activating or deactivating the sequential door opening If activated upon one unlocking command only driver s door...

Страница 9: ...ed is less than 15km h Activation when speed 15km h and deactivation possible by PDC control button Automatic re activation on ignition on Activation on rear gear with priority of switching off Same a...

Страница 10: ...press the programming button 8 times The unit confirms new the setting value with the corresponding number of light signals 6 Exceptions programmable output functions no 8 10 and 15 require additional...

Страница 11: ...programmed planned output functions from table 4 1 Output pin 1 1 24 17 Front parking sensors turning on 2 Output pin 1 polarity positive polarity LED is on positive LED is off negative 3 Output pin 2...

Страница 12: ...ogrammable input which is defined as horn control 8 Doors hood and trunk Constant level signal when any of the preprogrammed doors hood or trunk is open Programming sub sequence Any combination of doo...

Страница 13: ...ce frequency proportionate to vehicle crank rotation frequency 1 impulse sec corresponds with crank rotation frequency of 20rpm Signal is designed for determining estimated but not the exact rpm 15 Tr...

Страница 14: ...but not the exact speed 21 Brake Constant level signal when the brake pedal is pressed 22 Parking brake Constant level signal when parking brake is activated 23 Parking lights Constant level signal wh...

Страница 15: ...flash per impulse On some vehicles uneven lamp blinking may be observed while the impulses are fed evenly CAN bus or alternate 5 Horn control Trigger input constant activates the programmable output...

Страница 16: ...n disconnected The unit emits permanently short fast light signals Detach the power source and release the programming button 6 Specifications BATT ACC range 9V 15V Stand by power drain 4mA Power cons...

Страница 17: ...able polarity 200 mA 2 Blue yellow Programmable output with changeable polarity 200 mA 3 Black Ground of power supply reserved 4 White black Programmable output 50 mA 5 Green yellow Programmable outpu...

Отзывы: