TEC Electronics CANTEC-F2 Скачать руководство пользователя страница 16

 

 

CAN-bus 

5.

 

Reset to factory defaults

 

By hardware reset, all programmable settings and functions of the unit are restored to factory 

default and the vehicle recognition (group and sub-group) is erased. To restore factory defaults: 

 

Detach the unit from power source and CAN-bus. 

 

Press and hold the programming button. 

 

With the programming button pressed, supply power to the unit (CAN-bus must remain 

disconnected). The unit emits permanently short fast light signals. 

 

Detach the power source and release the programming button. 

 
 
 

6.

 

Specifications 

 
BATT/ACC range 

 

 

9V ~ 15V 

Stand-by power drain  

 

<4mA 

Power consumption   

 

9W 

Temperature range   

 

-40°C to +85°C 

Weight (box with harness)   

45g 

Dimensions (box only) B x H x T 

30 x 30 x 7 mm 

 
 
 
 
 

 

7.

 

Technical Support 

 
NavLinkz GmbH 

 

 

 

 

 

       TEC electronics ltd 

 

EU-distribution and tech dealer-support

 

 

 

       

manufacturer

 

 

 

Eurotec-Ring 45 

 

 

 

 

16th Parkovaya 30, Bld.1 

 

 

D-47445 Moers 

 

 

 

 

105484 Moscow, Russia 

 
Tel 

+49 2841 94997 0 

Email  [email protected] 
http://www.navlinkz.de 

 

 

 

http://www.canbus-alarm.com 

 
 
 

 

Содержание CANTEC-F2

Страница 1: ...18 12 2019 CAN bus CAN bus interface CANTEC F2 CAN bus interface with USB support for analogue car alarms PDC more...

Страница 2: ...rogrammable output input configuration complete Product features CANTEC F2 is a universal CAN bus interface hereafter referred to as unit designed for connecting after market car alarm security park d...

Страница 3: ...which of the available programmable input and output functions are needed for the specific installation see chapter 4 2 Maximum currents of the unit s programmable inputs and outputs must match conne...

Страница 4: ...gnition 50 mA 7 Yellow red Programmable output PDC LED 50 mA 8 Green Programmable input PDC control button 1 5 mA 9 Blue Programmable input Unlock central door locking 1 5 mA 10 Brown red CAN high of...

Страница 5: ...ic vehicle recognition After installing the unit to power and CAN bus by carrying out a set of simple actions see vehicle specific installation file for procedure the vehicle specific group and sub gr...

Страница 6: ...button 1 time The unit confirms the selection with repeated single light signals 4 Enter vehicle group number by pressing the programming button for the corresponding number of times see vehicle spec...

Страница 7: ...ight signals There is no countdown until programming mode is deactivated 5 Change the option s setting value exception option no 9 PDC control button see table 2 instead by pressing the programming bu...

Страница 8: ...tial door opening disabled LED is on the function is on LED is off the function is off Activating or deactivating the sequential door opening If activated upon one unlocking command only driver s door...

Страница 9: ...ed is less than 15km h Activation when speed 15km h and deactivation possible by PDC control button Automatic re activation on ignition on Activation on rear gear with priority of switching off Same a...

Страница 10: ...press the programming button 8 times The unit confirms new the setting value with the corresponding number of light signals 6 Exceptions programmable output functions no 8 10 and 15 require additional...

Страница 11: ...programmed planned output functions from table 4 1 Output pin 1 1 24 17 Front parking sensors turning on 2 Output pin 1 polarity positive polarity LED is on positive LED is off negative 3 Output pin 2...

Страница 12: ...ogrammable input which is defined as horn control 8 Doors hood and trunk Constant level signal when any of the preprogrammed doors hood or trunk is open Programming sub sequence Any combination of doo...

Страница 13: ...ce frequency proportionate to vehicle crank rotation frequency 1 impulse sec corresponds with crank rotation frequency of 20rpm Signal is designed for determining estimated but not the exact rpm 15 Tr...

Страница 14: ...but not the exact speed 21 Brake Constant level signal when the brake pedal is pressed 22 Parking brake Constant level signal when parking brake is activated 23 Parking lights Constant level signal wh...

Страница 15: ...flash per impulse On some vehicles uneven lamp blinking may be observed while the impulses are fed evenly CAN bus or alternate 5 Horn control Trigger input constant activates the programmable output...

Страница 16: ...n disconnected The unit emits permanently short fast light signals Detach the power source and release the programming button 6 Specifications BATT ACC range 9V 15V Stand by power drain 4mA Power cons...

Страница 17: ...able polarity 200 mA 2 Blue yellow Programmable output with changeable polarity 200 mA 3 Black Ground of power supply reserved 4 White black Programmable output 50 mA 5 Green yellow Programmable outpu...

Отзывы: