CAN-bus
8.
Customer-specific programmable output/input configuration (complete)
For reason of better comprehension, in chapter 4.2., programmable outputs and inputs are
separated. Full configuration can be noted in the below table. For support reasons, we also
suggest to apply the extra serial number sticker in CANTEC-F2 box here:
________________
Pin definition and customer-specific outputs/inputs configuration
Pin
no.
Harness wire
color
Functionality
Factory default
settings
Maximum
current
1
Blue/red
Programmable output (+ / -)
with changeable polarity*
200 mA
2
Blue/yellow
Programmable output (+ / -)
with changeable polarity*
200 mA
3
Black
Ground of power supply
reserved
4
White/black
Programmable output (+)
50 mA
5
Green/yellow
Programmable output (-)
50 mA
6
Pink/green
Programmable output (+)
50 mA
7
Yellow/red
Programmable output (+)
50 mA
8
Green
Programmable input (-)
1.5 mA
9
Blue
Programmable input (-)
1.5 mA
10
Brown/red
CAN-high of vehicle data
bus
reserved
11
Brown
CAN-low of vehicle data bus reserved
12
Red
+12V of power supply
reserved
13
Gray/black
Programmable output (-)
50 mA
14
Gray/blue
Programmable output (-)
50 mA
15
Gray/green
Programmable output (-)
50 mA
16
Gray/yellow
Programmable output (-)
50 mA
17
Orange/white
Programmable input (+)
1.5 mA
18
Orange/green
Programmable input (-)
1.5 mA