background image

 

- 14 - 

After Sales Technical Service 

In case of technical problems regarding any of the Tebas heat pumps, the following measures should be taken: 

Provide to the technical service the following essential information: 

Serial number of the machine 

Manometer value when machine is stopped 

Manometer value when machine is working 

The position of ON/OFF button and if it is lit or not 

The value and pictograms displayed on digital controller. 

The value of programmed settings 

If fan is working or not 

Position of the by-pass valves 

Contact  your  dealer  and  pass  on  this  information together  with  the  dimensions  of  the  swimming  pool,  your  personal 

details (address, telephone number) and the description of the failure. 

If this procedure is respected, the Tebas technician will be able to make as accurate diagnostic of the failure.  

The recommended solution made by Tebas will be implemented briefly after that. 

 IMPORTANT: If this measure is not followed, warranty will be cancelled. 

 

Contains fluorinated greenhouse gases covered by the Kyoto protocol in a hermetically sealed circuit: 

-

 

R32: 

 

100% CH2F2 

 

 

At the end of product lifetime, it must imperatively be entrusted to a qualified professional (refrigeration technician) in 

order to dismantle it in accordance with the laws in force (recovery of cooling gas, of metallic materials which can 
be recycled...).

 

Содержание INVERTER S

Страница 1: ...Handbook Tebas Inverter 20 1 Angielska docx Inverter...

Страница 2: ...on 5 Installation conditions 5 Hydraulic connections 6 Electrical connections 6 Heating priority 7 Utilization 8 Water connection 8 Regulation digital controller 9 Water flow setting 12 Winter setting...

Страница 3: ...hours The heat pump referred to in this handbook is designed and built solely for private swimming pool use Tebas dissociates its responsibility if used in any other application This handbook is cons...

Страница 4: ...th automatic start up fan Cutting edges evaporator In order to avoid accidents prevent close access the appliance by children and pets Never cover the appliance whilst in operation and never put your...

Страница 5: ...t side of the fan on a completely free space Make sure that the discharged air will not be sucked back into the evaporator again Provide enough space to allow access to temperature controller To impro...

Страница 6: ...on the floor or the walls so the heat pump will not support the weight of the water inside the plumbing Do not use a clamp or other tool to screw the connections hand screwing is sufficient Electrica...

Страница 7: ...y water gas they must be separated by a distance of at least 20 cm 8 Heat pump power supply must be protected by a system in conformity with local laws Heating priority It is possible to connect the w...

Страница 8: ...emperature is between 15 and 30 C 50 F and 86 F You can then start up your machine Follow the instructions below in the given order each time you start up the pool heat pump especially at the beginnin...

Страница 9: ...the machine manage its power and keep low noise low speed Heats the water up to the desired value 1 C Smart Heating mode machine manage it s power for best efficiency Heats the water up to the desire...

Страница 10: ...Adjust the desired value with or and wait a few seconds till it is stored automatically Working information 3 symbols at the left bottom corner indicate the working information First symbol indicate...

Страница 11: ...ater flow switch position Contact your seller AL10 AL11 HP error AL15 AL16 Too much temperature difference between water in and water out AL18 Comp Out temp Too high AL17 Low temp protection in coolin...

Страница 12: ...2 C by pass setting is correct between 10 and 15 C Abnormal pressure If the pressure is too high or too low it indicates that the water flow circulating inside the heat pump is not correct You need to...

Страница 13: ...nds on the exposure of swimming pool to wind sun and the pool environment as well as the heat pump size Maintaining the temperature Once the set temperature is reached you may reduce the filtration pe...

Страница 14: ...rmation together with the dimensions of the swimming pool your personal details address telephone number and the description of the failure If this procedure is respected the Tebas technician will be...

Отзывы: