Tebas INVERTER S Скачать руководство пользователя страница 12

 

- 12 - 

Water flow setting 

To  optimize  the  performance  of  the  heating  process,  it is  advisable  to  regulate  the  water flow  through  the  pool  heat 

pump. 

The adjustment must be carried out according to the indication given by the pressure gauge. The setting is modified by 

opening or closing the setting valve of the by-pass. 

To  increase  the  pressure  on  the  manometer  (pressure  gauge),  the  water  flow  passing  through  the  heat  pump  must 

decrease: 

Open the setting valve.

 

 

To  decrease  the  pressure  on  the manometer  (pressure  gauge),  the  water flow  passing  through  the  heat  pump must 

increase: 

Close the setting valve. 

For a normal working performance, inlet and outlet valves must be completely open. 

Normal pressure 

Pressure inside the refrigerant circuit of the heat pump and the water flow influence each other. 

To work correctly, a water flow of 5 to 7 m³/h (100 l/min) should be maintained for maximum heat transfer. 

Ideal by-pass setting is obtained when the manometer needle indicates (when working in heating boost Hi mode for 

several minutes) a temperature between 10 to 15°C higher than the swimming pool water temperature. 

Warning: The Heat pump needs to operate for few minutes before the internal pressure stabilizes 

Example : Swimming pool water is at 20°C, heat pump is working for 5 minutes in heating boost (Hi) mode, and the 

needle indicates 20 bars / 280 PSI / 32 °C / 90 °F. 

 32°C 

– 20 °C = 12°C 

 by-pass setting is correct (between 10 and 15°C) 

Abnormal pressure 

If the pressure is too high or too low, it indicates that the water flow circulating inside the heat pump is not correct. 

You need to adjust the water flow by opening or closing the by-pass valve. Open little by little it if the pressure is too 

low and close it little by little if the pressure is too high until it remains stable in the correct area. 

When heat pump is stopped the temperature indicated by the needle should be close to water temperature. 
If the value is 0, don’t start the machine (contact your seller). 

Frequency of settings 

The optimum water flow through the pool heat pump depends mainly on the water temperature and to a lesser extent 

on the ambient air temperature.  

Ideally the settings should be done: 

 

When the pool heat pump is turned on and water is cold. 

 

When the pool temperature is increasing. 

 

When the desired water temperature is reached. 

Thereafter the flow  does  not  need  to  be  regulated  any  further.  Simply  check  the  pressure  once  in  a  while to  ensure 

that the pool heat pump is working normally and that the water flow hasn't changed. 

 
Winter setting 

When you are winterizing your pool system, you must: 

 

Turn the pool heat pump off 

 

Close downstream and upstream valves of the by-pass system. 

 

Drain the exchanger to prevent any risk of freezing. 

 

Open completely the downstream and upstream valves to empty the heat exchanger tank before closing them. 

 

Cover the heat pump with a water-proof cover. 

A special cover designed for each heat pump model can be provided as an option. 

 

 

Содержание INVERTER S

Страница 1: ...Handbook Tebas Inverter 20 1 Angielska docx Inverter...

Страница 2: ...on 5 Installation conditions 5 Hydraulic connections 6 Electrical connections 6 Heating priority 7 Utilization 8 Water connection 8 Regulation digital controller 9 Water flow setting 12 Winter setting...

Страница 3: ...hours The heat pump referred to in this handbook is designed and built solely for private swimming pool use Tebas dissociates its responsibility if used in any other application This handbook is cons...

Страница 4: ...th automatic start up fan Cutting edges evaporator In order to avoid accidents prevent close access the appliance by children and pets Never cover the appliance whilst in operation and never put your...

Страница 5: ...t side of the fan on a completely free space Make sure that the discharged air will not be sucked back into the evaporator again Provide enough space to allow access to temperature controller To impro...

Страница 6: ...on the floor or the walls so the heat pump will not support the weight of the water inside the plumbing Do not use a clamp or other tool to screw the connections hand screwing is sufficient Electrica...

Страница 7: ...y water gas they must be separated by a distance of at least 20 cm 8 Heat pump power supply must be protected by a system in conformity with local laws Heating priority It is possible to connect the w...

Страница 8: ...emperature is between 15 and 30 C 50 F and 86 F You can then start up your machine Follow the instructions below in the given order each time you start up the pool heat pump especially at the beginnin...

Страница 9: ...the machine manage its power and keep low noise low speed Heats the water up to the desired value 1 C Smart Heating mode machine manage it s power for best efficiency Heats the water up to the desire...

Страница 10: ...Adjust the desired value with or and wait a few seconds till it is stored automatically Working information 3 symbols at the left bottom corner indicate the working information First symbol indicate...

Страница 11: ...ater flow switch position Contact your seller AL10 AL11 HP error AL15 AL16 Too much temperature difference between water in and water out AL18 Comp Out temp Too high AL17 Low temp protection in coolin...

Страница 12: ...2 C by pass setting is correct between 10 and 15 C Abnormal pressure If the pressure is too high or too low it indicates that the water flow circulating inside the heat pump is not correct You need to...

Страница 13: ...nds on the exposure of swimming pool to wind sun and the pool environment as well as the heat pump size Maintaining the temperature Once the set temperature is reached you may reduce the filtration pe...

Страница 14: ...rmation together with the dimensions of the swimming pool your personal details address telephone number and the description of the failure If this procedure is respected the Tebas technician will be...

Отзывы: