Technical data
TIG 180 AC/DC puls
299-020200-TWD01
14.07.2017
53
8
Technical data
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
TIG 180 AC/DC puls
TIG
MMA
Setting range for welding current
3 A
–180 A
3 A
–140 A
Setting range for welding voltage
10.1 V
–17.2 V
20.2 V
–25.6 V
Duty cycle (DC) at 40 °C
35% DC
180 A
-
50% DC
-
140 A
60% DC
150 A
130 A
100% DC
120 A
110 A
Load cycle
10 min. (60% DC
6 min. welding, 4min. pause)
Open circuit voltage (DC)
43 V
Mains voltage (tolerances)
1 x 230 V (
–40% to +15%)
Frequency
50/60 Hz
Mains fuse
1 x 16 A
Mains connection lead
H07RN-F3G2,5
Max. connected load
5.3 kVA
6.0 kVA
Recommended generator rating
8.1 kVA
cos
/efficiency
0.99/85%
Insulation class/protection classification
H/IP 23
Ambient temperature
–25
C to +40
C
Machine cooling/torch cooling
Fan/gas
Noise level
< 70 dB(A)
Workpiece lead
35 mm
2
EMC class
A
Safety identification
/
/
Harmonised standards
used
see declaration of conformity (machine
documentation)
Dimensions L x W x H
600 x 205 x 415 mm
Weight
16.5 kg
1
DIAZED xxA gG safety fuses are recommended. When using automatic cutouts, the "C" trigger
characteristic must be used.