Design and function
Machine configuration menu
44
299-020200-TWD01
14.07.2017
Display
Setting/selection
Lock JOB menu
Protect welding parameters from unauthorised access.
Machine code
Querying the three-digit machine code (000 to 999), user input
Error
Error message after entering an incorrect machine code
Switch on
Switching on machine function
Switch off
Switching off machine function
Torch configuration menu
Set welding torch functions
Torch mode setting (factory setting 1)
Up-/Down speed (not available in modes 4 and 14)
Increase value
= rapid current change
Reduce value
= slow current change
Settings
Settings for machine functions and parameter displays.
Welding current display, percentage
Representation of the welding current as a percentage in relation to the main current
setting (AMP). Example: Main current setting to 120A and secondary current to 50%
results in an absolute secondary current of 60A.
Welding current display, absolute
Absolute representation of all welding currents in amperes
TIG antistick
> see 5.3.8 chapter
------ function active (factory setting).
------ function inactive.
Time-based power-saving mode
> see 5.8 chapter
Time to activation of the power-saving mode in case of inactivity.
Setting
=
disabled or numerical value 5
– 60 min. (ex works: 20).
TIG HF start (soft/hard) switching
------- soft ignition (factory setting).
------- hard ignition.
Negative welding current polarity during the ignition phase
Positive welding current polarity during the ignition phase
Alternating current welding with sinusoidal current waveform
Low noise level
Alternating current welding with trapezoidal current waveform
An all-rounder, suitable for most applications
AC welding with rectangular current waveform (ex works)
Highest energy input
Service menu
Service settings
Machine fan test
Machine fan is switched off