TEAM
O
MARINE.COM
TEAM
O
MARINE.COM
5
4
Inflating your lifejacket
1. When fitted with auto inflation firing head the lifejacket will automatically deploy within 5 seconds of
entering the water.
2. If the lifejacket does not deploy or is not fitted with an automatic firing head, it can be manually
inflated by pulling the red or yellow toggle on the right side of the lifejacket as worn.
3. Oral inflation and top up can be achieved by opening the cover on
the left side of lifejacket as worn, removing the valve cap on the
red inflation tube and blowing into the tube.
4. Deflating the lifejacket after use:
Reverse the cap on top of the oral inflation tube and insert it into
the valve in the top of the tube. Squeeze the lifejacket bladder
to expel the air. If the lifejacket has been inflated using the gas
cylinder take care not to inhale the expelled gas. Remove the cap
from its reversed position and place over the top of the tube.
WARNING! If this lifejacket has been partially inflated by mouth, subsequent operation of
the operating head may result in bursting the lifejacket bladder.
NOTE!
It is recommended that you only use
TeamO
disposable CO
2
gas cylinders and automatic
firing capsules in this lifejacket. Please contact
TeamO
to order your re-arming kit when required.
For service and repacking guides visit
www.teamomarine.com
WARNING! In cold environments the inflation may be slower and lower performance may
result. Do not use in temperatures below -5° Centigrade.
WARNING!
The deck safety harness and safety line are intended to prevent the user falling overboard. They
do not provide protection against falls from a height.
WARNING!
The deck safety harness and
safety line may transmit very large forces. Only attach to strong hooking points or jack-lines.
WARNING!
It is unsafe to wear this harness loose, the harness must be worn tightly in order to
be effective. Inspect the harness before each use for any signs of damage. If damaged please
contact
TeamO
or an approved
TeamO
Service Station.
Check
www.teamOmarine.com
Auto to Manual Conversion
Jackets with the Prosensor Elite firing system can be fitted with blanking caps to allow easy conversion
from automatic inflation to manual only inflation. To convert the jacket unzip the cover to allow access to
the cylinder and firing head.
Convert the cylinder and ensure it’s
full and has not been pierced before
screwing back in, hand tight.
Take a
TeamO
blanking cap and fit it to the
firing head, hand tighten over the automatic
capsule. Re-pack the jacket in accordance
with the packing instructions.
The automatic capsule indicator identifies the
CO
2
cylinder status. Red indicates that it is
missing or has been pierced.
Check the status of your jacket before use.
Servicing your TeamO Lifejacket
Service your jacket every 2 years (minimum), at an authorised station to retain your warranty. An annual
service by an authorised service station is highly recommended.
For professional frequent and extreme use we recommend a full service annually from date of purchase
and within the automatic capsule expiry date. For leisure users 2 years full service from the date of
purchase and within the capsule expiry date.
NOTE!
Lifejacket should be serviced at a service station accredited by the manufacturer within one
month either side of the service date. Visit
www.teamomarine.com
for details about servicing
WARNING!
Gas cylinders are dangerous and must be kept away
from children and never misused.
>
50kg
ADULT
68-144cm
UL 2821
38g CO
2
170N Jacket
Pull Toggle
Sealing Cap
Manual
Deployment
Indicator
Automatic
Capsule Indicator