Scale Indicator Manual 917-5

Your T20 series scale is warranted to be free 
from defects in materials or workmanship under 
normal use during the limited warranty period.

The warranty period starts on the date of 
purchase from your authorized Te Pari scale 
agent. Please keep the dated sales receipt for 
proof of purchase as you may be required to 
provide proof of purchase as a condition of 
receiving warranty service.

Te Pari scales carry a 1 year limited warranty. 
The rechargeable batteries carry a 1 year limited 
warranty. The battery warranty does not cover 
changes in battery charge capacity and is limited 
to defects in materials or workmanship resulting 
in battery failure.

During the limited warranty period, your scale 
will be repaired or replaced, either the defective 
component or product. All components removed 
under this warranty become the property of 
Te Pari. The replacement component will take 
on either the remaining warranty period of 
the removed component or a ninety (90) day 
limited warranty for the spare part, whichever 
is longer. The replacement component maybe 
manufactured from new or used materials 
equivalent to new in performance and reliability. 
Te Pari reserves the right to improve or modify 
products from time to time without assuming 

obligation to modify products previously 
manufactured.

Te Pari is not responsible for damage that occurs 
as a result of (1) failure to follow the instructions 
that came with the product; (2) accident, misuse, 
abuse or other external causes; (3) voltage surge 
or lightning strike; (4) modification, tampering or 
service by an unauthorized service provider.

Te Pari is not liable for any damages or personal 
injury caused by the product or the failure of the 
product to perform, including any damage or loss 
of data on the product or computer.

The maximum liability of Te Pari under this limited 
warranty is limited to the lesser of the cost of 
repair or the replacement of the product.

In the event of the product requiring servicing 
under the terms of the warranty contact your 
authorized dealer.The product is to be returned 
to the service center at the expense of the 
purchaser.

These conditions constitute the complete and 
exclusive warranty and supersede all other 
warranties, representations or conditions relating 
to this product.

Te Pari Scale Indicators 
All rights reserved

Care, maintenance and storage

Your Te Pari scale can run from either the internal rechargeable batteries or the 12v power adaptor. 
Use only the supplied power adaptor to both power and charge the scale. 

The power adaptor is rated for indoor use only. Charge at temperatures between 0 to 30 C (32 to 86 F).

Run time is 6 hours at 240 C with the back light on. Full recharge time is 8 hours.

Operating temperature is between -10 and 400 C (14 to 1040 F).
If operating the unit below 0C ensure the battery is fully charged.

Your scale is environmentally sealed and water proof to the IP66 standard.

Do not submerge in water. Do not tamper with or remove the case screws, this will void the warranty.

Store your scale in a clean, dry place, out of direct sunlight. Storage temperature is between -10 and  
350 C (14 to 950F). Store above 00 C for optimum battery performance.

The lens has a scratch resistant coating however take care when cleaning. Clean the LCD lens and keypad 
lightly with a soft clean cloth and a cleaner suitable for use on polycarbonate plastic.

Warranty

Содержание T10

Страница 1: ...de Te Pari Scale Indicator Manual www tepari com Covering T10 and T20 models including E series Te Pari Direct Support USB Card Installation and use of Te Pari Connect and Downloader Software Te Pari...

Страница 2: ...tery D USB Wi Fi dongle plugs into a USB port on your PC to connect to your scale using Wi Fi E Te Pari scale mounting bracket and 2x U bolts for fixing the bracket to a post if required F 12 Volt pow...

Страница 3: ...scale indicator 16 Connecting using Wi Fi 16 Direct cable connection to your PC or device 17 Connecting to a PC or device using Bluetooth 18 Getting the latest software for your scale using your Te P...

Страница 4: ...ed cable COM ports COM1 and COM2 Both plug styles are shown here These attach the scale to other devices like computers etc Each port uses a different address so if one won t connect you may need to t...

Страница 5: ...main working area TALLY FILENAME STOCK B EID VID FAST1 REC CODE1 DRAFT PREV WGT IVOMEC TOT GAIN DRENCH ml ml 95 0KG 9 2 1 0000 0 0000 0 15 0087 Health dosage 2 display area When Health Mode 2 is off...

Страница 6: ...right arrows change the items setting The term arrow to in this guide refers to using the arrows to select or change an item using the arrow buttons The RECORD SELECT button is used to confirm your se...

Страница 7: ...Bluetooth PHONE COMPUTER Loadbar Model T1000 Description Te Pari DR3 Drafter Gate 1 0000 0 0050 0 OFF Gate 2 0050 1 0070 0 OFF Gate 3 0070 1 0090 0 OFF Gate 4 0090 1 0300 0 OFF Gate 5 0000 0 0000 0 O...

Страница 8: ...Usually Com Plug 1 is set to PHONE COMPUTER Arrow to Loadbar Model then use the left and right arrows to select your correct loadbar model from the list It is important that this is set correctly for...

Страница 9: ...or OFF When set to ON the Starting at number field is shown and you can key in your preferred starting number The VID number issued increases from your starting number by 1 each time one is assigned...

Страница 10: ...ELECT button is pressed While held you can arrow to any entry on the main screen and adjust its properties This lets you make on the fly decisions based on observations during your session AUTO EID Th...

Страница 11: ...orth between them Running a What if scenario To see what happens to draft weights and quantities without changing your stored recorded data You can edit the weight ranges in the Wt Stats screen then s...

Страница 12: ...T 00123456789 123456789 STOCKB H The Statistics screen Data columns in the Statics menu Use the left and right arrows to scroll across the data columns as shown here Arrow to DOSING in the MAIN MENU a...

Страница 13: ...ATE EIDS Options are YES the default or NO If set to YES when a duplicate EID is scanned while autodrafting it will overwrite the duplicate record If NO it will stop and wait for operator confirmation...

Страница 14: ...for each of your 4 main tasks You can then load them and tweak the settings from there to suit your sessions needs A loaded favourite will not change when you alter settings you need to overwrite the...

Страница 15: ...described on page 22 Note Users of Windows 8 and above do not need to install the drivers as they are included with Windows so you can skip this step and can go to the top of the next page If your com...

Страница 16: ...e iScale entry and click Connect Working with files is handled in your application Now the connection is made you can run Te Pari Downloader to view and work with your files or if using a smart phone...

Страница 17: ...ial cable in to the Scales COM1 port Using the serial to serial cable Plug the other end of the serial to serial cable into a serial port on your computer Physical serial to serial connection is made...

Страница 18: ...Te Pari applications and drivers for use with your scale and its components The URL for the support centre is also printed on the card so you can type it into your web browser to go there Current appl...

Страница 19: ...oid or the Apple Store for Apple devices The screen shots shown in this guide are of the Android version Screens will vary depending on both the type of device you are using and the operating system i...

Страница 20: ...ready to run the Te Pari Connect App Once launched it prompts you to tap start to continue From the App list tap the Te Pari Connect icon You are now prompted to either connect and download new record...

Страница 21: ...re now prompted to provide a file name for the download the default name is the current date and time Tap save when finished All downloaded records on the device are listed Each file has a checkbox to...

Страница 22: ...also tap the Upload Email file tab from the view window to send the file on To forward your files on select the files checkboxes that you wish to forward then tap the Upload Email Selected tab You wi...

Страница 23: ...s send the email from Te Pari When done tap the back button You are returned to the What would you like to do screen Continue with another action or tap quit to exit then tap quit on the prompt Depend...

Страница 24: ...displayed Click Finish to exit the installer and return to your desktop You will notice a Macrostock Lite icon on your desktop and also under Start All Programs in a MacroStock Lite folder You can run...

Страница 25: ...whether or not you wish to go on the mailing list These same details also used when required when you forward data from the application Click the activate button The software will now be registered Th...

Страница 26: ...the System main menu Click the Home tab to be returned to the home tab The Scale image with its connection type listed below it should now appear in the left of the menu bar The connection is now comp...

Страница 27: ...gside A The Scale Downloader button Clicking this opens the files on the Scale in the usual working window B The Contacts button Clicking this opens the Contacts main area This is where you add and ed...

Страница 28: ...on a column title sorts the displayed records by that title Clicking the small arrow alongside the title toggles the sort between ascending and descending You can remove unwanted columns by clicking...

Страница 29: ...rds with XMD recorded in them and view a list of just these animals When done you can clear the filter with the same tool A B D C E A The Preview Export button When you click this the current file is...

Страница 30: ...below and changes depending on the file type that you have selected see the example below F Contacts List Allows you to add and modify your contacts directly from this area G Displays a list of the r...

Страница 31: ...h the menu bar Click on the Upload File button A to open the Upload File Screen shown below Click the Open File button B browse to the file you wish to upload select it C then click the Open button D...

Страница 32: ...l be available for selection from the File List screen on your scale C D A B E Te Pari Downloader software Deleting a file on your Te Pari Scale Indicator The downloader software allows you to delete...

Страница 33: ...33 Scale Indicator Manual 917 5 Notes...

Страница 34: ...e 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Страница 35: ...0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set Tag Recor...

Страница 36: ...te 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Страница 37: ...sing EID or visual tags and you want every tag read Set Tag Recording to ON RECORDING Recording Tag Recording ON Weight Gain Total Gain Auto Visual Tags ON Starting at number 0001 Code Recording OFF S...

Страница 38: ...holes in the top of the load bars so the two pieces can be bolted together It is best not to have these bolts too tight An evenly levelled concrete pad of a size greater than the platform or crush is...

Страница 39: ...ion Connect the load bars to your Te Pari indicator Turn on the indicator and press zero Place a test weight at one end of the platform and note the reading on the indicator The displayed weight shoul...

Страница 40: ...40 Scale Indicator Manual 917 5 Te Pari Standard and Heavy Duty load bars 1000 mm Heavy Duty load bar schematic 600 mm Standard load bar schematic...

Страница 41: ...is useful for quickly drafting or collecting statistics on a group of animals without recording any additional information EID status lights T20E model only Red Green Yellow SERVICE OK POWER Indicate...

Страница 42: ...service provider Te Pari is not liable for any damages or personal injury caused by the product or the failure of the product to perform including any damage or loss of data on the product or computer...

Страница 43: ...43 Scale Indicator Manual 917 5 Notes...

Страница 44: ...274 Australia 1800 650 682 USA 800 315 0433 International 64 03 433 0077 Head Office 9 Endeavour Crescent P O Box 25 Oamaru 9444 New Zealand REV 917 7 www tepari com For more information on our full...

Отзывы: