Te Pari T10 Скачать руководство пользователя страница 29

29

Scale Indicator Manual 917-5

Te Pari Downloader software - Opening and viewing your files

Te Pari Downloader software - Exporting, printing and filtering

The column sort actions are also available by right clicking on any 

column title. The functions list is displayed. These are self explanatory.
When you remove a column it will not be shown again on any file 

until it is reinstated. To do this right click on any column title to bring 

up the functions list and click on Column Chooser.
The categories not currently being displayed are listed. Double 

clicking on the column title/s you wish to reintroduce will restore it.
Note: removing the category title does not delete the information, 

it only stops displaying it. The data is still held in the record.

Other useful tools in the functions list include:
The find panel. Selecting this brings up a search panel at the top of the file window that you can use to search for 

specific entries.
The Filter Editor: Allows you to create a custom filter to refine your records.  e.g. you have recorded XMD against 

animals that you notice have missed docking during a draft. You can create a filter to view records with XMD 

recorded in them and view a list of just these animals. When done you can clear the filter with the same tool.

A

B

D

C

E

A

  The Preview/Export button. When you click this the current file is opened in a print preview window.

All the usual print formatting options are available here for you as shown below.

There are also 2 export buttons, highlighted above. These allow you to select from a drop down list of file format 

options and either save the file locally or to email it on. The Email option saves the file first then opens your email 

application with the file already attached ready for you to select the recipient.

B

  Export to Excel button. Select your preferred format, from the options below the button, then click the Export To 

Excel button. A standard Windows Save As dialogue box is opened. Provide a file and location and click Save. 

C

  Displays the currently active files name.

D

 Exports the file using a standard Windows Save As dialogue box for MINDA livestock systems (*xlsx format)

E

  Apply (Date) Filter button. The dates the records were taken are listed in the File Date: drop down menu box 

(shown below) you can select to view files from a single date by clicking the Apply Filter button.

When a date filter is applied the button changes to Remove Filter and 

clicking the button clears the filter and displays all date ranges.

Содержание T10

Страница 1: ...de Te Pari Scale Indicator Manual www tepari com Covering T10 and T20 models including E series Te Pari Direct Support USB Card Installation and use of Te Pari Connect and Downloader Software Te Pari...

Страница 2: ...tery D USB Wi Fi dongle plugs into a USB port on your PC to connect to your scale using Wi Fi E Te Pari scale mounting bracket and 2x U bolts for fixing the bracket to a post if required F 12 Volt pow...

Страница 3: ...scale indicator 16 Connecting using Wi Fi 16 Direct cable connection to your PC or device 17 Connecting to a PC or device using Bluetooth 18 Getting the latest software for your scale using your Te P...

Страница 4: ...ed cable COM ports COM1 and COM2 Both plug styles are shown here These attach the scale to other devices like computers etc Each port uses a different address so if one won t connect you may need to t...

Страница 5: ...main working area TALLY FILENAME STOCK B EID VID FAST1 REC CODE1 DRAFT PREV WGT IVOMEC TOT GAIN DRENCH ml ml 95 0KG 9 2 1 0000 0 0000 0 15 0087 Health dosage 2 display area When Health Mode 2 is off...

Страница 6: ...right arrows change the items setting The term arrow to in this guide refers to using the arrows to select or change an item using the arrow buttons The RECORD SELECT button is used to confirm your se...

Страница 7: ...Bluetooth PHONE COMPUTER Loadbar Model T1000 Description Te Pari DR3 Drafter Gate 1 0000 0 0050 0 OFF Gate 2 0050 1 0070 0 OFF Gate 3 0070 1 0090 0 OFF Gate 4 0090 1 0300 0 OFF Gate 5 0000 0 0000 0 O...

Страница 8: ...Usually Com Plug 1 is set to PHONE COMPUTER Arrow to Loadbar Model then use the left and right arrows to select your correct loadbar model from the list It is important that this is set correctly for...

Страница 9: ...or OFF When set to ON the Starting at number field is shown and you can key in your preferred starting number The VID number issued increases from your starting number by 1 each time one is assigned...

Страница 10: ...ELECT button is pressed While held you can arrow to any entry on the main screen and adjust its properties This lets you make on the fly decisions based on observations during your session AUTO EID Th...

Страница 11: ...orth between them Running a What if scenario To see what happens to draft weights and quantities without changing your stored recorded data You can edit the weight ranges in the Wt Stats screen then s...

Страница 12: ...T 00123456789 123456789 STOCKB H The Statistics screen Data columns in the Statics menu Use the left and right arrows to scroll across the data columns as shown here Arrow to DOSING in the MAIN MENU a...

Страница 13: ...ATE EIDS Options are YES the default or NO If set to YES when a duplicate EID is scanned while autodrafting it will overwrite the duplicate record If NO it will stop and wait for operator confirmation...

Страница 14: ...for each of your 4 main tasks You can then load them and tweak the settings from there to suit your sessions needs A loaded favourite will not change when you alter settings you need to overwrite the...

Страница 15: ...described on page 22 Note Users of Windows 8 and above do not need to install the drivers as they are included with Windows so you can skip this step and can go to the top of the next page If your com...

Страница 16: ...e iScale entry and click Connect Working with files is handled in your application Now the connection is made you can run Te Pari Downloader to view and work with your files or if using a smart phone...

Страница 17: ...ial cable in to the Scales COM1 port Using the serial to serial cable Plug the other end of the serial to serial cable into a serial port on your computer Physical serial to serial connection is made...

Страница 18: ...Te Pari applications and drivers for use with your scale and its components The URL for the support centre is also printed on the card so you can type it into your web browser to go there Current appl...

Страница 19: ...oid or the Apple Store for Apple devices The screen shots shown in this guide are of the Android version Screens will vary depending on both the type of device you are using and the operating system i...

Страница 20: ...ready to run the Te Pari Connect App Once launched it prompts you to tap start to continue From the App list tap the Te Pari Connect icon You are now prompted to either connect and download new record...

Страница 21: ...re now prompted to provide a file name for the download the default name is the current date and time Tap save when finished All downloaded records on the device are listed Each file has a checkbox to...

Страница 22: ...also tap the Upload Email file tab from the view window to send the file on To forward your files on select the files checkboxes that you wish to forward then tap the Upload Email Selected tab You wi...

Страница 23: ...s send the email from Te Pari When done tap the back button You are returned to the What would you like to do screen Continue with another action or tap quit to exit then tap quit on the prompt Depend...

Страница 24: ...displayed Click Finish to exit the installer and return to your desktop You will notice a Macrostock Lite icon on your desktop and also under Start All Programs in a MacroStock Lite folder You can run...

Страница 25: ...whether or not you wish to go on the mailing list These same details also used when required when you forward data from the application Click the activate button The software will now be registered Th...

Страница 26: ...the System main menu Click the Home tab to be returned to the home tab The Scale image with its connection type listed below it should now appear in the left of the menu bar The connection is now comp...

Страница 27: ...gside A The Scale Downloader button Clicking this opens the files on the Scale in the usual working window B The Contacts button Clicking this opens the Contacts main area This is where you add and ed...

Страница 28: ...on a column title sorts the displayed records by that title Clicking the small arrow alongside the title toggles the sort between ascending and descending You can remove unwanted columns by clicking...

Страница 29: ...rds with XMD recorded in them and view a list of just these animals When done you can clear the filter with the same tool A B D C E A The Preview Export button When you click this the current file is...

Страница 30: ...below and changes depending on the file type that you have selected see the example below F Contacts List Allows you to add and modify your contacts directly from this area G Displays a list of the r...

Страница 31: ...h the menu bar Click on the Upload File button A to open the Upload File Screen shown below Click the Open File button B browse to the file you wish to upload select it C then click the Open button D...

Страница 32: ...l be available for selection from the File List screen on your scale C D A B E Te Pari Downloader software Deleting a file on your Te Pari Scale Indicator The downloader software allows you to delete...

Страница 33: ...33 Scale Indicator Manual 917 5 Notes...

Страница 34: ...e 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Страница 35: ...0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set Tag Recor...

Страница 36: ...te 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Страница 37: ...sing EID or visual tags and you want every tag read Set Tag Recording to ON RECORDING Recording Tag Recording ON Weight Gain Total Gain Auto Visual Tags ON Starting at number 0001 Code Recording OFF S...

Страница 38: ...holes in the top of the load bars so the two pieces can be bolted together It is best not to have these bolts too tight An evenly levelled concrete pad of a size greater than the platform or crush is...

Страница 39: ...ion Connect the load bars to your Te Pari indicator Turn on the indicator and press zero Place a test weight at one end of the platform and note the reading on the indicator The displayed weight shoul...

Страница 40: ...40 Scale Indicator Manual 917 5 Te Pari Standard and Heavy Duty load bars 1000 mm Heavy Duty load bar schematic 600 mm Standard load bar schematic...

Страница 41: ...is useful for quickly drafting or collecting statistics on a group of animals without recording any additional information EID status lights T20E model only Red Green Yellow SERVICE OK POWER Indicate...

Страница 42: ...service provider Te Pari is not liable for any damages or personal injury caused by the product or the failure of the product to perform including any damage or loss of data on the product or computer...

Страница 43: ...43 Scale Indicator Manual 917 5 Notes...

Страница 44: ...274 Australia 1800 650 682 USA 800 315 0433 International 64 03 433 0077 Head Office 9 Endeavour Crescent P O Box 25 Oamaru 9444 New Zealand REV 917 7 www tepari com For more information on our full...

Отзывы: