Scale Indicator Manual 917-5

Te Pari Standard and Heavy Duty load bars

Installing Load bars - continued

The load bars can be bolted to the concrete pad or pinned in order to prevent movement.
For safety reasons, the load bars should be positioned as close to the ends of the platform or crush as 
practical. Any overhang should not exceed 150mm.
The load bar cables should be positioned so that potential damage is minimised. Keep cables away 
from animals so they cannot be chewed, walked on, or squashed in any way as any cable damage will 
affect the weight reading and require the complete loadbar to be returned to Te Pari for repair
The total weight of the platform or crush must rest upon the load bars in order to ensure accurate and 
consistent weight readings. Ensure that the load bars and platform are clear of any obstruction and 
that the installation is as level as possible. Good drainage is essential so that the load bars are not left 
sitting in puddles of muddy water.
Care when cleaning and hosing down to ensure no build-up of manure or mud around the load bars 
will extend the life of the load bars and prevent inaccuracies with weight readings.

CAUTION:

  Do not weld any metalwork that is in contact with the load bars. The load bars should 

be completely removed before any welding takes place as spurious currents will cause permanent 
damage to the load cells.

Testing the installation

 

 

Connect the load bars to your Te Pari indicator.

 

 

Turn on the indicator and press zero.

 

 

Place a test weight at one end of the platform and note the reading on the indicator.
The displayed weight should be stable.

 

 

Remove the weight, check that the display returns to zero, then place the weight at the other end 
of the platform and take note of the reading.

The weight reading should not vary by more than 1 kg from one end to the other and should return 
to zero when the weight is removed. If this is not the case then check that the load bars or platform 
are not binding on anything such as a fence post etc, the installation is level and secure, and that 
there has been no cable damage during the installation. If necessary, loosening the anchor bolts may 
relieve tension and allow better results.

Care and Maintenance

Te Pari load bars are designed to withstand the harsh conditions associated with sheep and cattle 
crates and platforms. Taking care with installation and maintenance will prolong their life and ensure 
accurate recording

  •

 

When weighing ensure the animal is fully on the platform.

  •

 

Keep the underside of the platform and around the load bars free of stones or muck build-up.

  •

 

Store your indicator in a clean and dry environment and keep the indicator, load bars and cable 
plugs away from water as much as possible. 

  •

 

The load bar cable plugs have caps which should always be screwed back on when not in use.
If possible position the plugs so that they are not exposed to the weather when not being used.

  •

 

When cleaning the loadbars do not direct a water blaster directly at the loadcell area.

.

Содержание T10

Страница 1: ...de Te Pari Scale Indicator Manual www tepari com Covering T10 and T20 models including E series Te Pari Direct Support USB Card Installation and use of Te Pari Connect and Downloader Software Te Pari...

Страница 2: ...tery D USB Wi Fi dongle plugs into a USB port on your PC to connect to your scale using Wi Fi E Te Pari scale mounting bracket and 2x U bolts for fixing the bracket to a post if required F 12 Volt pow...

Страница 3: ...scale indicator 16 Connecting using Wi Fi 16 Direct cable connection to your PC or device 17 Connecting to a PC or device using Bluetooth 18 Getting the latest software for your scale using your Te P...

Страница 4: ...ed cable COM ports COM1 and COM2 Both plug styles are shown here These attach the scale to other devices like computers etc Each port uses a different address so if one won t connect you may need to t...

Страница 5: ...main working area TALLY FILENAME STOCK B EID VID FAST1 REC CODE1 DRAFT PREV WGT IVOMEC TOT GAIN DRENCH ml ml 95 0KG 9 2 1 0000 0 0000 0 15 0087 Health dosage 2 display area When Health Mode 2 is off...

Страница 6: ...right arrows change the items setting The term arrow to in this guide refers to using the arrows to select or change an item using the arrow buttons The RECORD SELECT button is used to confirm your se...

Страница 7: ...Bluetooth PHONE COMPUTER Loadbar Model T1000 Description Te Pari DR3 Drafter Gate 1 0000 0 0050 0 OFF Gate 2 0050 1 0070 0 OFF Gate 3 0070 1 0090 0 OFF Gate 4 0090 1 0300 0 OFF Gate 5 0000 0 0000 0 O...

Страница 8: ...Usually Com Plug 1 is set to PHONE COMPUTER Arrow to Loadbar Model then use the left and right arrows to select your correct loadbar model from the list It is important that this is set correctly for...

Страница 9: ...or OFF When set to ON the Starting at number field is shown and you can key in your preferred starting number The VID number issued increases from your starting number by 1 each time one is assigned...

Страница 10: ...ELECT button is pressed While held you can arrow to any entry on the main screen and adjust its properties This lets you make on the fly decisions based on observations during your session AUTO EID Th...

Страница 11: ...orth between them Running a What if scenario To see what happens to draft weights and quantities without changing your stored recorded data You can edit the weight ranges in the Wt Stats screen then s...

Страница 12: ...T 00123456789 123456789 STOCKB H The Statistics screen Data columns in the Statics menu Use the left and right arrows to scroll across the data columns as shown here Arrow to DOSING in the MAIN MENU a...

Страница 13: ...ATE EIDS Options are YES the default or NO If set to YES when a duplicate EID is scanned while autodrafting it will overwrite the duplicate record If NO it will stop and wait for operator confirmation...

Страница 14: ...for each of your 4 main tasks You can then load them and tweak the settings from there to suit your sessions needs A loaded favourite will not change when you alter settings you need to overwrite the...

Страница 15: ...described on page 22 Note Users of Windows 8 and above do not need to install the drivers as they are included with Windows so you can skip this step and can go to the top of the next page If your com...

Страница 16: ...e iScale entry and click Connect Working with files is handled in your application Now the connection is made you can run Te Pari Downloader to view and work with your files or if using a smart phone...

Страница 17: ...ial cable in to the Scales COM1 port Using the serial to serial cable Plug the other end of the serial to serial cable into a serial port on your computer Physical serial to serial connection is made...

Страница 18: ...Te Pari applications and drivers for use with your scale and its components The URL for the support centre is also printed on the card so you can type it into your web browser to go there Current appl...

Страница 19: ...oid or the Apple Store for Apple devices The screen shots shown in this guide are of the Android version Screens will vary depending on both the type of device you are using and the operating system i...

Страница 20: ...ready to run the Te Pari Connect App Once launched it prompts you to tap start to continue From the App list tap the Te Pari Connect icon You are now prompted to either connect and download new record...

Страница 21: ...re now prompted to provide a file name for the download the default name is the current date and time Tap save when finished All downloaded records on the device are listed Each file has a checkbox to...

Страница 22: ...also tap the Upload Email file tab from the view window to send the file on To forward your files on select the files checkboxes that you wish to forward then tap the Upload Email Selected tab You wi...

Страница 23: ...s send the email from Te Pari When done tap the back button You are returned to the What would you like to do screen Continue with another action or tap quit to exit then tap quit on the prompt Depend...

Страница 24: ...displayed Click Finish to exit the installer and return to your desktop You will notice a Macrostock Lite icon on your desktop and also under Start All Programs in a MacroStock Lite folder You can run...

Страница 25: ...whether or not you wish to go on the mailing list These same details also used when required when you forward data from the application Click the activate button The software will now be registered Th...

Страница 26: ...the System main menu Click the Home tab to be returned to the home tab The Scale image with its connection type listed below it should now appear in the left of the menu bar The connection is now comp...

Страница 27: ...gside A The Scale Downloader button Clicking this opens the files on the Scale in the usual working window B The Contacts button Clicking this opens the Contacts main area This is where you add and ed...

Страница 28: ...on a column title sorts the displayed records by that title Clicking the small arrow alongside the title toggles the sort between ascending and descending You can remove unwanted columns by clicking...

Страница 29: ...rds with XMD recorded in them and view a list of just these animals When done you can clear the filter with the same tool A B D C E A The Preview Export button When you click this the current file is...

Страница 30: ...below and changes depending on the file type that you have selected see the example below F Contacts List Allows you to add and modify your contacts directly from this area G Displays a list of the r...

Страница 31: ...h the menu bar Click on the Upload File button A to open the Upload File Screen shown below Click the Open File button B browse to the file you wish to upload select it C then click the Open button D...

Страница 32: ...l be available for selection from the File List screen on your scale C D A B E Te Pari Downloader software Deleting a file on your Te Pari Scale Indicator The downloader software allows you to delete...

Страница 33: ...33 Scale Indicator Manual 917 5 Notes...

Страница 34: ...e 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Страница 35: ...0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set Tag Recor...

Страница 36: ...te 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Страница 37: ...sing EID or visual tags and you want every tag read Set Tag Recording to ON RECORDING Recording Tag Recording ON Weight Gain Total Gain Auto Visual Tags ON Starting at number 0001 Code Recording OFF S...

Страница 38: ...holes in the top of the load bars so the two pieces can be bolted together It is best not to have these bolts too tight An evenly levelled concrete pad of a size greater than the platform or crush is...

Страница 39: ...ion Connect the load bars to your Te Pari indicator Turn on the indicator and press zero Place a test weight at one end of the platform and note the reading on the indicator The displayed weight shoul...

Страница 40: ...40 Scale Indicator Manual 917 5 Te Pari Standard and Heavy Duty load bars 1000 mm Heavy Duty load bar schematic 600 mm Standard load bar schematic...

Страница 41: ...is useful for quickly drafting or collecting statistics on a group of animals without recording any additional information EID status lights T20E model only Red Green Yellow SERVICE OK POWER Indicate...

Страница 42: ...service provider Te Pari is not liable for any damages or personal injury caused by the product or the failure of the product to perform including any damage or loss of data on the product or computer...

Страница 43: ...43 Scale Indicator Manual 917 5 Notes...

Страница 44: ...274 Australia 1800 650 682 USA 800 315 0433 International 64 03 433 0077 Head Office 9 Endeavour Crescent P O Box 25 Oamaru 9444 New Zealand REV 917 7 www tepari com For more information on our full...

Отзывы: